AE-X15PU
Outdoor
Problem
unit
symptom
indication
(LED1)
Indoor and
12- ime
O O O O O Timer (Orange)
outdoor
units do not
operate.
Indoor and
13- ime
O O O O O Timer (Orange)
outdoor
units do not
operate.
O O O O O Timer (Orange)
O O O O O Timer (Orange)
Indoor and
O O O O O Timer (Orange)
outdoor units
operate.
Indoor and
14- ime
O O O O O Timer (Orange)
outdoor
units do not
operate.
O O O O O Timer (Orange)
O O O O O Timer (Orange)
Indoor unit
Lighting or
O O O O O Timer (Orange)
operates.
OFF
O
Outdoor unit
does not
operate.
Indoor unit
Lighting or
O O O O O Timer (Orange)
operates.
OFF
O
Outdoor unit
does not
operate.
Indoor and
O O O O O Timer (Orange)
outdoor
O
units do not
operate.
Malfunction
Indoor unit
Lamp
Main Sub
O O
Operation (Green)
Plasmacluster (Blue)
O O
O Operation (Green)
Plasmacluster (Blue)
O O
O Operation (Green)
O Plasmacluster (Blue)
O O
O Operation (Green)
O
Plasmacluster (Blue)
O O
O Operation (Green)
O O Plasmacluster (Blue)
O O O
Operation (Green)
Plasmacluster (Blue)
O O O
Operation (Green)
O Plasmacluster (Blue)
O O O
Operation (Green)
O
Plasmacluster (Blue)
O Operation (Green)
Plasmacluster (Blue)
O
Operation (Green)
Plasmacluster (Blue)
O
Operation (Green)
O Plasmacluster (Blue)
Content of diagnosis
No.*
Main
Sub
12
0
Thermal fuse
Thermal fuse error
in terminal
in terminal board (for
board
power supply)
13
0
DC
Compressor startup
compressor
error
1
Compressor rota ion
error.
(at 120° energizing)
2
Compressor rota ion
error
(at 180° energizing)
3
Detection error of
inverter current
14
0
Outdor unit
PAM over voltage
PAM
error
1
PAM clock error
2
PAM under voltage
error
17
0
Wiring
Serial opencircuit
between
units
18
0
Wiring
Serial opencircuit
between
units
1
3 – 16
Check point
Action
1) Check he thermal fuse
1) Replace terminal
in terminal board (for
board for Power
Power supply)
supply.
2) Check connector CN5 of
2) Correct he installa-
the outdoor unit.
tion.
3) 1) 2): Normal
3) Replace the outdoor
unit control PCB
assembly.
1) Check he colors (red,
1) Correct the installa-
white, orange) of the
tion.
compressor cords for
(U: Red, V: White, W:
proper connection.
Orange)
(PWB side, compressor
2) Replace the outdoor
side)
unit control PWB
2) Check if he IPM terminal
assembly.
resistance values are
3) Replace the outdoor
uniform.
unit control PWB
3) Check if outdoor main
assembly.
relay (MRY1) turns on
4) Replace the com-
and voltage of both end
pressor.
of the condenser (C8
or C9) has become
DC290-330V.
4) 1) 2) 3) : Normal
Check the circuit of
Replace the outdoor
detection of inverter
unit control PWB
current.
assembly.
1) Check the AC power
1) Correct he installa-
supply voltage for
tion.
2) Replace the PWB
2) No abnormality found in
assembly.
above inspection.
Check the PAM clock for
Replace the outdoor
proper input.
unit control PWB
assembly.
1) Check the AC power
1) Correct he installa-
supply voltage for
tion.
2) Replace the PWB
2) No abnormality found in
assembly.
above inspection.
1) Check he wires between
1) Connect stable
units.
power supply.
2) Check voltage between
Correct the wiring.
N and 1 the indoor/
2) Replace the outdoor
outdoor unit terminal
unit control PWB
boards.
assembly.
3) Check the outdoor unit
3) Replace the fuse/
fuse.
outdoor unit control
4) Check 15-V,12-V and
PWB assembly.
5-V voltages on the
4) Replace the outdoor
PCB.
unit control PWB
Check resistance between
assembly.
IPM terminals.
5) Replace the outdoor
5) Check pins No 3 and 5
unit fan motor.
of connector CN3 of he
6) Replace the outdoor
outdoor unit fan motor
unit control PWB.
for shortcircuit.
6) Outdoor unit control
PCB.
Check the wiring between
Correct the wiring.
units.
Check the wiring between
Correct the wiring.
units.