Sharp AE-X15PU Service Manual page 18

Split type room air conditioner (outdoor unit)
Table of Contents

Advertisement

AE-X15PU
F
u
n
t c
o i
n
11
Thermistor installa-
Compressor stops if high and low
tion error or 4-way
values of temperatures detected
valve error
by outdoor unit heat exchanger
thermistor (TH2) and 2-way valve
thermistor (TH5) do not match
operating cycle.
12 Compressor high
Compressor stops if compressor
temperature error
chamber thermistor (TH1)
exceeds about 114℃ , or if there
is short-circuit in TH1.
13 Outdoor unit heat
Compressor stops if there is
exchanger ther-
short-circuit in outdoor unit heat
mistor short-circuit
exchanger thermistor (TH2).
error
14 Outdoor unit outside
Compressor stops if there is
air temperature
short-circuit in outdoor unit out-
thermistor short-cir-
side air temperature thermistor
cuit error
(TH3).
15 Outdoor unit suction
Compressor stops if there is
thermistor short-cir-
short-circuit in outdoor unit suc-
cuit error
tion thermistor (TH4).
16 Outdoor unit 2-way
Compressor stops if there is
valve thermistor
short-circuit in outdoor unit 2-way
short-circuit error
valve thermistor (TH5).
17 Outdoor unit heat
Compressor stops if there is
exchanger ther-
open-circuit in outdoor unit heat
mistor open-circuit
exchanger thermistor (TH2).
error
18 Outdoor unit outside
Compressor stops if there is
air temperature
open-circuit in outdoor unit out-
thermistor open-cir-
side air temperature thermistor
cuit error
(TH3).
19 Outdoor unit suction
Compressor stops if there is
thermistor open-cir-
open-circuit in outdoor unit suc-
cuit error
tion thermistor (TH4).
20 Outdoor unit 2-way
Compressor stops if there is
valve thermistor
open-circuit in outdoor unit 2-way
open-circuit error
valve thermistor (TH5).
21 Outdoor unit dis-
Compressor stops if there is
charge thermistor
open-circuit in outdoor unit dis-
open-circuit error
charge thermistor (TH1).
22 Serial signal error
Power relay turns OFF if indoor
unit cannot receive serial signal
from outdoor unit for 8 minutes.
Compressor stops if outdoor unit
cannot receive serial signal from
indoor unit for 30 seconds.
23 Compressor star-
Compressor stops if compressor
tup error
fails to start up.
24 Compressor rota-
Compressor stops if there is no
tion error (at 120°
input of position detection signal
energizing)
from compressor or input is
abnormal.
25 Outdoor unit DC fan
Operation stops if there is no
error
input of rotation pulse signal from
outdoor unit fan motor for 30 sec-
onds.
26 PAM over voltage
Compressor stops if DC voltage is
error
350 V or higher.
O
Description
Detection period
3 minutes after com-
pressor startup
When in operation
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
At compressor star-
tup
When in operation
When in operation
At compressor star-
tup
Compressor operat-
ing at 120° energizing
When outdoor unit
fan is in operation
When in operation
p
r e
t a
o i
n
Reset condition
Operation OFF or ON Yes I1
Operation OFF or ON YesI1
Operation OFF or ON Yes I1
Operation OFF or ON YesI1
Operation OFF or ON Yes I1
Operation OFF or ON Yes I1
Operation OFF or ON Yes I1
Operation OFF or ON Yes I1
Operation OFF or ON Yes I1
Operation OFF or ON Yes I1
Operation OFF or ON YesI1
Operation OFF or ON
(Automatic reset
when less than 8 min-
utes)
Reset after reception
of serial signal
Operation OFF or ON Yes I3
Operation OFF or ON Yes I3
Operation OFF or ON Yes I1
Operation OFF or ON Yes I1
3 – 2
S
e
f l
d -
a i
g
n
o
s
s i
result display
Indoor
Indoor
Outdoor
unit
unit
unit
error
display
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
None
None
None
None
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes