AE-X15PU
Outdoor
Problem
unit
symptom
indication
(LED1)
Indoor and
5-time
O O O O O Timer (Orange)
outdoor
units do not
operate.
O O O O O Timer (Orange)
O O O O O Timer (Orange)
O O O O O Timer (Orange)
O O O O O Timer (Orange)
O O O O O Timer (Orange)
Indoor and
6-time
O O O O O Timer (Orange)
outdoor
units do not
operate.
O O O O O Timer (Orange)
Indoor and
7-time
O O O O O Timer (Orange)
outdoor
units do not
operate.
O O O O O Timer (Orange)
O O O O O Timer (Orange)
O O O O O Timer (Orange)
Indoor and
8-time
O O O O O Timer (Orange)
outdoor
units do not
O
operate.
Malfunction
Indoor unit
→
Lamp
Main Sub
5
O
O Operation (Green)
Plasmacluster (Blue)
O
O Operation (Green)
O Plasmacluster (Blue)
O
O Operation (Green)
O
Plasmacluster (Blue)
O
O Operation (Green)
O O Plasmacluster (Blue)
O
O Operation (Green)
O
Plasmacluster (Blue)
O
O Operation (Green)
O
O Plasmacluster (Blue)
6
O O
Operation (Green)
Plasmacluster (Blue)
O O
Operation (Green)
O Plasmacluster (Blue)
7
O O O Operation (Green)
Plasmacluster (Blue)
O O O Operation (Green)
O Plasmacluster (Blue)
O O O Operation (Green)
O
Plasmacluster (Blue)
O O O Operation (Green)
O O Plasmacluster (Blue)
8
Operation (Green)
Plasmacluster (Blue)
Content of diagnosis
No.*
Main
Sub
0
Outdoor unit
Heat exchanger
thermistor
thermistor open
open-circuit
circuit error
1
Outdoor temperature
thermistor open
circuit error
2
Suction thermistor
open circuit error
3
Suction thermistor
open circuit error
4
Discharge thermistor
open circuit error
5
Heat sink thermistor
open circuit error
0
Outdoor unit
DC over current
DC Current
error
1
IPM pin level error
0
Outdoor unit
AC over current error 1) Ensure unobstructed air
AC Current
1
AC current error
when OFF
2
AC maximum current
error
3
AC current
0
Abnormal
Abnormal wire check
wire check
error
3 – 14
Check point
Action
1) Check connector of
1) Correct the installa-
outdoor unit thermistor
ion
for secure installa ion.
2) Replace the outdoor
2) Measure resistance of
unit thermistor
outdoor hermistors
assembly.
3) Check the lead wires
3) Replace the outdoor
of hermistors on the
unit thermistor
outdoor unit control
assembly.
PCB for open-circuit.
4) 1) 2) 3):Normal
4) Replace the outdoor
unit control PWB
assembly.
Go to "DC Over Current Error (6-0 error)".
Check the IPM is attached
Replace the outdoor
correctly to the outdoor unit
unit IPM PWB
IPM PWB.
assembly.
1) Ensure unobstructed
unit air outlet.
outdoor unit air
outlet.
2) Check the outdoor unit
fan motor.
2) Check the outdoor
unit fan motor.
1) IPM con inuity check
1) Replace the outdoor
IPM PWB
1) Ensure unobstructed air
1) Ensure unobstructed
unit air outlet.
outdoor unit air
outlet.
2) Check the outdoor unit
fan motor.
2) Check the outdoor
unit fan motor.
1) Replace the outdoor unit
1) Replace the outdoor
control PCB assembly.
unit control PCB
assembly.
amount of refrigerant.
amount of refriger-
3) Correct refrigerant clogs.
ant.
(Stop valve, pipe,
expansion valve)
3) Correct refrigerant
clogs. (Stop valve,
pipe, expansion
valve)
1) Check the expansion
1) Replace the outdoor
valve.
control board
assembly.
2) Are four expansion
valves connected by
2) Reattach
mistake.
3) Check the wiring
3) Check the wiring
between units.
between units.