Sharp AY-X09MCJ Operation Manual

Split type inverter room air conditioner

Advertisement

Quick Links

Split Type Inverter Room Air Conditioner
Thank you for selecting SHARP air-conditioner. Please read this manual
carefully before operation and keep it for further reference.
OPERATION MANUAL
MODELS
AY-X09MCJ
AY-X12MCJ
AY-X18MCJ
AE-X09MCJ
AE-X12MCJ
AE-X18MCJ

Advertisement

loading

Summary of Contents for Sharp AY-X09MCJ

  • Page 1 Split Type Inverter Room Air Conditioner OPERATION MANUAL MODELS AY-X09MCJ AE-X09MCJ AY-X12MCJ AE-X12MCJ AY-X18MCJ AE-X18MCJ Thank you for selecting SHARP air-conditioner. Please read this manual carefully before operation and keep it for further reference.
  • Page 3 and cleaning Specifications NOTE:All the pictures in this manual are just schematic diagrams. The actual product is the standard. that should be prevented. that Collection of such waste should be separated for special treatment as required by local regulations.
  • Page 6 To change the airflow direction, adjust the vertical and lateral air flow direction by using the , pl ease ref er the mat ter to remote control. a qualified air conditioner contractor. objects Don’t expose animals and plants directly to the output air flow as it may have a detrimental effect on them.
  • Page 7 Air conditioners absorb heat in the room and transmits it to the outdoor unit, so that indoor ambient temperatures are decreased. Its cooling capacity will increase or decrease according to outdoor ambient temperature. If the unit is running in COOL mode and in low ambient temperature, frost may be formed on the heat exchanger.
  • Page 8: Name And Function Of Each Part

    Na me and function of each part X-FAN...
  • Page 9 Note: Be sure that there are no obstructions between receiver and remote control; Don't drop or throw the remote control; Don't spill any liquid on the remote control; Don't leave remote control directly in sunlight or hot environments. Pres s this button to turn Sleep mode on or off.
  • Page 10 Name and function of wireless remote control Some buttons on this control are not applicable to this unit. Preset temperature is increased by pressing this button. Continuously pressing and holding for 2 seconds changes the temperature rapidly. X-FAN X-FAN Preset temperature is decreased by pressing this button.
  • Page 11 Some buttons on this control are not applicable to this unit. Press this button to select Timer On setting. Pressing the + or - button during the first 5 seconds adjusts the time value by one minute each time pressed. Holding the + or - button down for more than 2 seconds changes the time rapidly.
  • Page 12 Press On /Off button to start or stop operation. to switch On or Off the display on the main unit. odels to switch X-FAN x-fan the fan will con tinue to after the unit is stopped to remove X-FAN X-FAN X-FAN X-FAN function is not operated.
  • Page 13 o set the guide louvre to a desired position, press Swing Up and Down button continuously for more than 2 seconds and hold until desired position is achieved. Releasing the button now stops the swinging at the desired position. After Swing Up and Down mode is switched on, pressing the button again within 2 seconds circulates between the various settings.
  • Page 14 on the main unit. Operation will be in Auto Run mode and the temperature setting or fan speed cannot be changed. To operate: Press the AUTO/STOP button and the unit will enter into AUTO RUN mode. The microcomputer will monitor the room temperature to select the (COOL, HEAT, FAN) mode automatically, to obtain the comfortable effect.
  • Page 15: Care And Cleaning

    Care and Cleaning at the circuit breaker to prevent the risk of electric shock. pour or spray liquids directly onto the indoor or outdoor units for cleaning, to prevent risk of electric shock. Only wipe the Rotate the front panel upwards in the direction of the arrow.
  • Page 16 Care and Cleaning Removing Rotate the front panel upwards in the direction of the arrow. Pull the air filter downwards and remove from the unit. water temperature should be and leave to dry naturally in a shady location. Never dry it with a heater or open flame, as fire or deformation may occur.
  • Page 17 The air conditioner is not user serviceable. if attempt to If a bad smell has been accumulated from the environment, clean the air filter. If smells persist, contact your Approved Service Centre to arrange cleaning. fluid gurgling noises. This is not a fault - it is the sound of flowi ng refrigerant.
  • Page 18 will Has the circuit breaker device tripped off? Have the wiring or connections been damaged?Please report to an authorised air conditioner contractor. Is the fan other working Check that there is no magnetic or electrical interference near the main unit that may be affecting the operation of the controller.
  • Page 19 flow is stopped fros t can be for med on the outdoor heat exchanger. The unit will automatically defrost and the indoor unit will stop blowing air for 3-12 mins. During defrost operation, water or vapour may be emitted. ,disconnect from the power supply, and report to an authorised air conditioner contractor in the following situations.
  • Page 20 The unit must only be installed by authorised air conditioner contractors according to municipal or government regulations and in compliance wi th this manual. The unit should be installed with a dedicated electrical circuit, and a circuit breaker should be fitted in accordance with regulations. Proper installation position is vital for correct and efficient operation.
  • Page 21 A dedicated power supply circuit should be used, in accordance with local electrical safety regulations. The product should be installed by a licenced air conditioning contractor in accordance with AS/NZS3000 and your electrical supplier's rules. A circuit breaker should be installed. WARNING: inadequate or incorrect electrical connections may cause electrocution or fire.
  • Page 22: Installation Dimension Diagram

    Installation dimension diagram Installation dimension diagram Installation dimension diagram Space to the ceiling Above 15cm Above 15cm Above Space to the wall Space to the wall cm cm Above Above Air outlet side Space to the floor Space to the obstruction Air inlet side 30cm Above...
  • Page 23: Installing The Indoor Unit

    Installing the indoor unit , and leveled to ensure correct drainage. Wall Wall Gradienter Mark on the middle of it Space to Space to the wall the wall 150mm 150mm above above Left Right Fig.1 (Rear piping hole) (Rear piping hole) proper Drainage hoses passing through indoor areas should be wrapped with insulation material.
  • Page 24 Installing the indoor unit All interconnecting wiring between indoor and outdoor unit must be performed by a licenced electrical contractor in accordance with AS/NZS3000. unit to screws adequately to prevent loosening. Ensure the electrical connections are properly earthed to prevent electrical shocks. Ensure all wiring connections are secure and the cover plates are reinstalled properly.
  • Page 25: Installing The Outdoor Unit

    Installing the Outdoor Unit Remove electrical connection access plate (either right hand side or front) from the outdoor unit. Replace access plate (either right hand side or front) on the outdoor unit. Incorrect unit failure. has been fitted,...
  • Page 26 Installing the Outdoor Unit soapy gas detection are leaking. Outdoor attach satisfactorily.
  • Page 27 satisfactory to the product. product. Are the inlet and outlet air openings blocked? Is the quantity of gas charge sufficient may be for the length of pipe run? insufficient.
  • Page 28: Specifications

    Specifications Model AY-X09MCJ;AE-X09MCJ Function COOLING HEATING Rated Voltage 220-240V Frequency(Hz) (High/Standard *) 50HZ Total Capacity (W) (High/Standard *): 3300/2600/ 1188(W) 3800/2850/1109 (W) Total Capacity (Btu/h) (High/ Standard *): 11200/9000/4063(Btu/h) 13000/9800/3792(Btu/h) Power Input (W) (High/ Standard*) 1200/610/264 1250/670/230 Rated Input (W) (High/ Standard *)
  • Page 29 AE-X09MCJ Model of Outdoor Unit Compressor SANYO Manufacturer/trademark Compressor Model C-6RZ110H1A Compressor Type Twin rotory L.R.A. (A) Compressor RLA(A) 4.59 Compressor Power Input(W) Overload Protector Int11l-3979 Throttling Method Capillary throttling Starting Method Transducer starting Working Temp Range (℃) -7℃≤T≤43℃ Condenser Aluminum fin-copper tube Rows-Fin Gap(mm) 2-1.4...
  • Page 30 Model AY-X12MCJ;AE-X12MCJ Function COOLING HEATING Rated Voltage 220-240V~ Frequency(Hz) (High/Standard *) 50HZ Total Capacity (W) (High/Standard /min*): 4000/3500/ 1233(W) 4100/3850/830 (W) Total Capacity (Btu/h) (High/ Standard /imin*): 13600/12000/4200(Btu/h) 14000/13000/2830(Btu/h) Power Input (W) (High/ Standard*) 1400/1000/262 1450/1066/233 Rated Input (W) (High/ Standard *) 1400 1450 Rated Current (A) (High/ Standard *)
  • Page 31 AE-X12MCJ Model of Outdoor Unit Compressor Manufacturer/trademark SANYO Compressor Model C-6RZ110H1A Compressor Type Double Rotary L.R.A. (A) Compressor RLA(A) 4.59 Compressor Power Input(W) Overload Protector Int11l-3979 Throttling Method Capillary throttling Starting Method Transducer starting Working Temp Range (℃) -7℃≤T≤43℃ Condenser Aluminum fin-copper tube Rows-Fin Gap(mm) 2-1.4...
  • Page 32 Model AY-X18MCJ;AE-X18MCJ Function COOLING HEATING Rated Voltage 220-240V~ Rated Frequency 50Hz 5650/5300/1610 W 6260/5600W/1217 W Total Capacity (W/Btu/h) 19300/18000/5500 (Btu/h) 21350/19100/4150 (Btu/h) Power Input (W) 2100/1540/ 370 W 2300/1610/ 398 W Rated Input (W) 2450 2650 Rated Current (A) 10.7 11.5 /h) (H/M/L) 830/670/600...
  • Page 33 AE-X18MCJ Model of Outdoor Unit Compressor Manufacturer/trademark SANYO Compressor Model C-6RVN93H0N Compressor Type Double Rotary L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) 1610 Overload Protector 1NT11L-3979 Throttling Method Capillary Starting Method capacitor Working Temp Range (℃) -7℃≤T≤43℃ Condenser Aluminum fin-copper tube Rows-Fin Gap(mm) 2-1.4 Coil length (l) x height (H) x coil width (L)
  • Page 35 SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.au OR CALL SHARP CUSTOMER CARE 1300 135 022 (LOCAL CALL COST APPLY WITHIN AUSTRALIA) SHARP CORPORATION OF AUSTRALIA PTY LTD SHARP FOR LOCATION ENQUIRIES WITHIN NEW ZEALAND REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.nz...
  • Page 36 SHARP CORPORATION OF AUSTRALIA PTY LTD ABN 40 003 039 405 1 Huntingwood Drive HUNTINGWOOD NSW 2148 www.sharp.net.au 66129905916...