Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Sharp Manuals
Air Conditioner
AE-X15PU
Service manual
Sharp AE-X15PU Service Manual page 20
Split type room air conditioner (outdoor unit)
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
page
of
46
Go
/
46
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
AE-X15PU
1. Outdoor unit
Item
Mode
Compressor
Cooling
chamber ther-
Dehumidifying
mistor (TH1)
Heating
Heat exchanger
Cooling
thermistor (TH2)
Dehumidifying
Heating
Outside air tem-
Auto
perature ther-
mistor (TH3)
Cooling
Dehumidifying
Heating
Suction pipe ther-
Cooling
mistor (TH4)
Dehumidifying
Heating
2-way valve ther-
Cooling
mistor (TH5)
Dehumidifying
Heating
Control opera-
When resis-
tion
tance is low
(temperature
judged higher
than actual)
Expansion valve
Compressor
control and com-
operates, but
pressor protection
room does not
become cool or
warm (expansion
valve is open).
Outdoor unit heat
Compressor
exchanger over-
operates at low
heat prevention
speed or stops.
Expansion valve
Defrosting opera-
control
tion is not acti-
Defrosting
vated as needed,
and frost accumu-
lates on outdoor
unit (expansion
valve is closed).
Operation mode
Cooling mode is
judgment
activated even if
room tempera-
ture is low.
Operation not
Normal operation.
affected
Rating control
Defrosting opera-
Defrosting
tion is activated
unnecessarily.
Expansion valve
Compressor
control
operates, but
room does not
become cool
(expansion valve
is open).
Expansion valve
Compressor
control
operates, but
room does not
become warm
(expansion valve
is open).
Expansion valve
Frost accumu-
control
lates on indoor
unit evaporator
and room does
not become cool
(expansion valve
is closed).
Operation not
Normal operation.
affected
3 – 4
Short-circuit
When resis-
tance is high
(temperature
judged lower
than actual)
Compressor high
Layer short-cir-
temperature error
cuit or open-cir-
indication.
cuit may result in
compressor in
normal operation.
Outdoor unit ther-
Normal operation.
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
Defrosting opera-
mistor short-cir-
tion is activated
cuit error
unnecessarily,
indication.
and room does
not become warm
(expansion valve
is open).
Outdoor unit ther-
Heating mode is
mistor short-cir-
activated even if
cuit error
room tempera-
indication.
ture is high.
Outdoor unit ther-
Normal operation.
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
Defrosting opera-
mistor short-cir-
tion is not acti-
cuit error
vated, and frost
indication.
accumulates on
outdoor unit.
Outdoor unit ther-
Frost accumu-
mistor short-cir-
lates on evapora-
cuit error
tor inlet section,
and room does
indication.
not become cool
(expansion valve
is closed).
Outdoor unit ther-
Frost accumu-
mistor short-cir-
lates on expan-
cuit error
sion valve outlet
indication.
section, and room
does not become
warm (expansion
valve is closed).
Outdoor unit ther-
Compressor
mistor short-cir-
operates, but
cuit error
room does not
indication.
become cool
(expansion valve
is open).
Outdoor unit ther-
Normal operation.
mistor short-cir-
cuit error
indication.
Open-circuit
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Table of
Contents
Previous
Page
Next
Page
1
...
17
18
19
20
21
22
23
24
Show Quick Links
Quick Links:
Specification
Chapter 3. Function and Operation
General Troubleshooting Chart
Troubleshooting Guide
Outdoor Unit
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Troubleshooting
GENERAL TROUBLESHOOTING CHART
22
TROUBLESHOOTING GUIDE
28
Related Manuals for Sharp AE-X15PU
Air Conditioner Sharp AE-X12FR Service Manual
Sharp split type room air conditioner service manual (15 pages)
Air Conditioner Sharp AE-X09LCJ Operation Manual
Split type inverter room air conditioner (36 pages)
Air Conditioner Sharp Plasmacluster AE-X12HR Operation Manual
Split type room air conditioner (87 pages)
Air Conditioner Sharp AY-XP9LSR Service Manual
(60 pages)
Air Conditioner Sharp AY-X09MCJ Operation Manual
Split type inverter room air conditioner (36 pages)
Air Conditioner Sharp AY-XP07ER Service Manual
Split type room air conditioners (16 pages)
Air Conditioner Sharp AY-X12PSR Service Manual
Split type room ac (74 pages)
Air Conditioner IVT AY-XP12FR Operation Manual
Split type room air conditioner (24 pages)
Air Conditioner Sharp AY-XPC18LR Service Manual
Split type room air conditioner (52 pages)
Air Conditioner Sharp AY-XP9RMR Operation Manual
Split type room air conditioner (144 pages)
Air Conditioner Sharp AH-X08CR Service Manual
(49 pages)
Air Conditioner Sharp AY-XP08CE Operation Manual
Eco inverter split type room air conditioner (24 pages)
Air Conditioner Sharp AH-X08BE Operation Manual
Eco inverter split type room air conditioner (20 pages)
Air Conditioner Sharp AE-X9USR Installation Manual
Split type room air conditioner (11 pages)
Air Conditioner Sharp AH-X127E Service Manual
(46 pages)
Air Conditioner Sharp AH-X108E Service Manual
Split type room air conditioners (56 pages)
Related Products for Sharp AE-X15PU
Sharp AE-X15ZU
Sharp Plasmacluster AE-X12FR
Sharp AE-X18LCJ
Sharp AE-X127J
Sharp Plasmacluster AE-X12HR
Sharp Plasmacluster AE-X12LSR
Sharp AE-X12MCJ
Sharp AE-X18MCJ
Sharp AE-X12NCJ
Sharp AE-X12ER
Sharp AE-X12RMR
Sharp AE-X13CR
Sharp AE-X10BE-C
Sharp AE-X127E
Sharp AE-X108E
Sharp AE-X138E
This manual is also suitable for:
Ae-x18pu
Ae-x24pu
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL