Download Print this page

Specifications Terminal - Opticon PHL 2700 User Manual

With rf - identification feature
Hide thumbs Also See for PHL 2700:

Advertisement

RF-ID
SUPPLEMENT
6
SPECIFICATIONS
6.1

SPECIFICATIONS TERMINAL

6.1.1 Electrical specifications
Main battery
rechargeable pack: Ni-MH
dry cell: Alkaline penlite
optional: other 2 x AA-size
Main battery
Ni-MH: When having every 10
operating time
Alkaline: When having every
0.4 sec. green LED, 0.4 sec.
0,2 sec. RFIDtag writing,
Different operation conditions
Use of other penlite batteries
Backup battery
Lithium (CR2032)
Backup battery
If fully charged: 30 days backup
operating time
time
Battery
Low voltage indicated on the
management
terminal display.
When battery is low the
terminal switches off
Charging method
Rechargeable Ni-MH pack in
penlite
seconds on:
1 sec laser,
0.4 sec. green LED, 0.4 sec.
buzzer, 1 sec. RFIDtag reading,
0,2 sec. RFIDtag writing,
operating time is: approx.
22 hours
10 seconds on:
1 sec laser,
buzzer, 1 sec. RFIDtag reading,
operating time is: approx.
43 hours
affect the operating time
affect the operating time
automatically.
terminal via cradle
S
PHL2700
UPPLEMENT
6.1.5 Environmental specifications
Emission
Immunity
R&TTE
Additional specifications
Specifications RF-ID module
(RF-ID tag reading)
Reading range up to 15 mm,
dependent on type of RF-ID tag.
Supported RF Tags at 13.56 MHz
Philips I-Code
Texas Instruments Tag-It
ISO 15693
Supported RF Tags at 134.2 kHz
Texas Instruments TIRIS
/ RF-ID
TERMINAL
FEATURE
According to EN50081, part 1
According to EN50082, part 1
conform I-ETS 300-330
5