FMC Technologies AccuLoad II Programming Workbook page 43

Electronic preset delivery system perating with rbu 00 firmware
Hide thumbs Also See for AccuLoad II:
Table of Contents

Advertisement

Program
Code
Function Code
725-739
740
Protection of Program
Codes 780-789
741
Communication Link
Programming
742
Communications
Time-out
743
Communications
Alarm Mode
744
Prompt Time-out
Note: Minimum time-out is 10 seconds.
745
Prompt Data Entry #1
746
Prompt Data Entry #2
38
Description
Unassigned at Present
Enter:
"0" for Weights and Measures Mode
"1" for Program Mode
Enter:
"0" for No Program Code Values
"1" for Program Values Only
"2" for Program and Weights and
Measures Values
"3" for Alarm Reset Only
Enter:
Three digits in seconds
that communication polling may
be absent (e.g., 060)
"000" disables the Communications
Alarm Mode
Enter:
"0" Standby Mode
"1" Communications Alarm Mode
"2" Standby and Communications
Alarm Mode
Enter:
Three digits in seconds
of time-out allowed with each
prompt (e.g., 015)
Enter:
Two digits representing
the prompt data response.
First digit "0" = Displayed
First digit "1" = Hidden Display
Second digit "0 - 9" = Digits for
prompt entry (e.g., 04)
Enter:
Two digits representing
the prompt data response.
First digit "0" = Displayed
First digit "1" = Hidden Display
Second digit "0 - 9" = Digits for
prompt entry (e.g., 15)
Entry
__
__
__ __ __
__
__ __ __
__ __
__ __
Issue/Rev. 03 (8/97)
Program
Code
725-739
740
741
742
743
744
745
746