Strobe doesn't Fire
Typical causes:
•
S9 contact bent
•
Defective strobe
•
Green and orange wires reversed
•
Flashtube assembly defective
•
Orange wire not connected to strobe
•
White trigger wire not soldered or cold soldered
•
Flashtube not seated
•
Flashtube assembly incorrectly assembled
•
S1/S10 not held down in snap
Strobe Fires at Wrong Time
Typical causes:
•
Poor LCD module connection (See Poor LCD Module Connection, Page 4-9)
LEDs don't Light or Light at Wrong Time
Typical causes:
•
Poor LCD module connection (See Poor LCD Module Connection, Page 4-9)
•
Defective LED - replace LCD module
Ranging Incorrect
Typical causes:
•
S9 never open
•
S9, S10 short on wireform switch block
•
Defective RM
•
Defective transducer
•
Quintic not free
•
Ranging in wrong units (feet/meters): check jumper W1, LCD module
•
Defective encoder
•
Poor LCD module connection (See Poor LCD Module Connection, Page 4-9)
•
Defective LCD module