Quintic Hangs Up

Typical causes:
Quintic post distorted
Quintic frame damaged
Counterweight
Quintic return spring
Encoder wire not seated
Flash on baseblock

Strobe Exposure Adjustment Failure

Typical causes:
Photodiode cap not seated
Cal wedges not seated, missing or distorted (check IC, pin 7)
Transducer clip broken
Defective flashtube
Defective strobe

Ambient Exposure Adjustment Failure

Typical causes:
Cal wedges not seated, missing or distorted
Photodiode cap not seated
Yellow dot in wrong position (do not remove any yellow dots)
Adjusting gear wheel not catching wedge