12.3 Steam generation system

CAUTION!
Dry the steam generator after
each use. Remove the water with
the sponge.
Remove the limescale with water
and vinegar.
CAUTION!
Chemical de-scaling agents can
cause damage to the enamel. Fol-
low the instructions of the manu-
facturer.
Cleaning the water drawer and the
steam generator:
1.
Put the water and vinegar mixture
(approximately 250 ml) through the
water drawer into the steam genera-
tor. Wait for approximately 10 mi-
nutes.
2.
Remove the water and vinegar with
the sponge.
3.
Put clean water (100 - 200 ml) into
the water drawer to flush the steam
generation system.
4.
Remove the water from the steam
generator with the sponge and rub it
dry.
5.
Keep the door open to let the appli-
ance dry fully.
12.4 Lamp
WARNING!
There is a risk of electrical shock.
The lamp and the lamp glass cov-
er can be hot.

12.5 Cleaning the oven door

Removing the door and the glass panels
You can remove the oven door and the
internal glass panels to clean it. The num-
ber of glass panels is different for different
models.
WARNING!
Be careful when you remove the
door from the appliance. The door
is heavy.
Before you change the lamp:
• Deactivate the appliance.
• Remove the fuses from the fuse box or
deactivate the circuit breaker.
CAUTION!
Put a cloth on the bottom of the
interior of the appliance. It pre-
vents damage to the lamp glass
cover and the cavity.
Always use the same lamp type.
Replacing the lamp at the cavity
ceiling:
1.
Turn the lamp glass cover counter-
clockwise to remove it.
2.
Remove the metal ring and clean the
glass cover.
3.
Replace the lamp with a suitable 300
°C heat-resistant lamp.
4.
Attach the metal ring to the glass cov-
er.
5.
Install the glass cover.
Replacing the lamp on the left side of
the cavity:
1.
Remove the left shelf support.
2.
Use a Torx 20 screwdriver to remove
the cover.
3.
Remove and clean the metal frame
and the seal.
4.
Replace the lamp with a suitable 300
°C heat-resistant lamp.
5.
Install the metal frame and the seal.
Tighten the screws.
6.
Install the left shelf support.