Midea MCH2U-18PHH2 Service Manual page 107

Multi outdoor/ condensing units multi zone
Table of Contents

Advertisement

6)
Remove the IPM board.
7)
Disconnect the
connectors and wires
connected from PCB and other
parts.
Connectors:
CN17:T3/T4 temperature sensor
(2p/2p,white)
CN7: Discharge temperature sensor
(2p,white)
CN15:T2B-A,B temperature sensor
(2p/2p,white)
CN18/CN19: Electronic expansive
valve A,B (6p/6p,red/red)
CN25/CN23: S-A,S-B
(3p/3p,white/white)
Wires:
CN1/CN2: 4-way valve (blue-blue)
CN5/CN6: Crankcase heating cable
(red-red)
CN3:L-IN (red)
CN4:N-IN (black)
8)
Disconnect the
grounding wire (yellow-green)
after removing the big handle
and the right-rear panel.
9) Remove the PCB board.
CN17
CN1/CN2
107
CN15
CN18/CN19 CN25/CN23
CN7
CN4
CN3
CN5/CN6