Drive Programming
9 Insertion Point ( MX2 & RX )
The Gain/Bias can be applied to any reference
9-1 'Frequency' before ACC/DEC
Parameter
A901
A902
A903
9-2 'Frequency' after ACC/DEC
Parameter
A901
A904
A905
9-3 'Deviation' before PID block
Parameter
A901
A906
A907
Description
Insertion Point
Insertion Point 'Frequency' before ACC/Dec Gain
Insertion Point 'Frequency' before ACC/DEC Bias
Description
Insertion Point
Insertion Point 'Frequency' after ACC/Dec Gain
Insertion Point 'Frequency' after ACC/DEC Bias
Description
Insertion Point
Insertion Point 'Deviation' before PID block Gain
Insertion Point 'Deviation' before PID block Bias
0: Disable; 1: Enable
0 to 1000%
-100 to +100%
0: Disable; 1: Enable
0 to 1000%
-100 to +100%
0: Disable; 1: Enable
0 to 1000%
-100 to +100%
81
Range
Range
Range