5.2 I Technical specifi cati ons
Z300
PM30
EverFirst
Operati ng
temperature range
Defrosti ng by forced air
circulati on
Defrosti ng by cycle inversion
Voltage
Acceptable variati on in
voltage
Polluti on class
Polluti on degree
Overvoltage category
Nominal absorbed
intensity
Maximum absorbed
intensity
Minimum cable
secti on*
Proof pressure
Service pressure
Head loss
Medium water fl ow
* Values provided for informati on purposes for a maximum length of 20 metres (calculati on base: NFC15-100), must be
checked and adapted to the installati on conditi ons and standards of the installati on country.

5.3 I Dimensions and marking

Front
: Base
: Front panel
: Cover
: Technical access door
Overall dimensions
19
Reversible
M4
M5
PM3041 PM3051 PM3053 PM3061 PM3052 PM3056 PM3072 PM3076
8M
11M
air
5 to 38 °C
water
X
X
220-240V
220-240V
-50Hz
-50Hz
A
7.9
10.3
A
10
13
mm²
3x2.5
3x2.5
3G2.5
3G2.5
bar
bar
mCE
1.4
1.5
m³/h
4
5
Side
: Rear panel
: Column
: Grid
: User interface
T5
M7
MD5
11T
13M
11MD
10 to 32 °C
X
X
X
X
380-415V
220-240V
220-240V
-50Hz
-50Hz
-50Hz
± 6 % (during operati on)
I
2
II
4.25
13
10
4.7
15.7
12.8
5x2.5
3x4
3x2.5
5G2.5
3G4
3G2.5
3
1.5
1.5
1.5
1.5
5
6
5
Rear
: Ø1'' 1/2 pool water intake
: Ø1'' 1/2 pool water output
: Evaporator
: Gland
Standards
TD5
MD8
TD8
11TD
15MD
15TD
-8 to 38 °C
X
X
X
X
X
X
380-415V
220-240V
380-415V
-50Hz
-50Hz
-50Hz
4.4
16
7.4
5
24
9.3
5x2.5
3x6
5x2.5
5G2.5
3G6
5G2.5
1.5
1.1
1.1
5
6.5
6.5
H0548600.B - EN - 2016-05