I Operati Ng; I User Functi Ons - Zodiac Z300 M4 Instructions For Installation And Use Manual

Z300 series,pm30 series, everfirst series
Table of Contents

Advertisement

2.3 I Operati ng

• Check that there are no tools or other foreign objects in the machine.
• The panel that provides access to the technical secti on must be put in place.
• Set the valves as follows: valve B wide open, valves A, C, D and E closed
• An incorrect by-pass setti ng may cause the heat pump to malfuncti on.
• Check that the hydraulic correcti ons are correctly ti ghtened and that there are no leaks.
• Check that the device is fully stable.
• Set the water circulati on running.
• Close valve B gradually so that the fi lter pressure is increased by 150g (0.150 bars).
• Open valves A, C and D fully then valve E by half (the air which has built up in the heat pump condenser and the
fi ltrati on circuit will bleed out). If valves D and E are not present, open valve A wide and close valve C by half.
• Connect the power supply to the heat pump.
• If the heat pump is on standby
seconds then
and setpoint temperatures are displayed
• Set the temperature you want ("setpoint" temperature).
Aft er the start-up steps for your heat pump:
• Shut down the water circulati on temporarily (by stopping the fi ltrati on or closing valve B or C) to check that you
device stops aft er a few seconds (via the acti vati on of the fl ow rate controller).
• Reduce the setpoint temperature to below the water temperature to check that the heat pump stops operati ng.
• Switch off the heat pump by pressing and holding

2.4 I User functi ons

2.4.1 Adjusti ng the temperature set point:
• Press
to increase the temperature by 0.5 °C,
• Press
to reduce the temperature by 0.5 °C.
The heat pump stops automati cally when the pool reaches the required temperature.
2.4.2 Locking/unlocking the keyboard
Press and hold
and
9
: water entry valve
: by-pass valve
: water exit valve
: water entry adjustment valve (opti onal)
: water exit adjustment valve (opti onal)
(diff erent soft ware No. depending on the devices) for 3 seconds , and the water
for 3 seconds:
, press for 3 seconds
,
, a 2 miute ti mer will start.
for 3 seconds and check that it stops
or
appears for 2
.
.
H0548600.B - EN - 2016-05

Advertisement

Table of Contents
loading

Table of Contents