• Failure to respect the warnings may cause serious damage to the pool equipment or cause serious injury, even
death.
• The appliance is intended for a specifi c pool use and must not be used for any use other than that for which it was
designed.
• It is important that the equipment is operated by competent and qualifi ed (both physically and mentally) people
who have previously received the instructi ons for use. All persons not meeti ng these criteria must not approach the
appliance in order to avoid exposure to dangerous elements.
• Keep the appliance out of the reach of children.
• The device must be installed by a qualifi ed technician according to the manufacturer's instructi ons and in compliance
with local regulati ons. The installer is responsible for installati on of the equipment and for compliance with nati onal
installati on regulati ons. Under no circumstances can the manufacturer be held liable in the event of failure to
comply with applicable local standards.
• Incorrect installati on and/or use may cause serious damage to property or serious injuries (possibly causing death).
• All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The consignee shall make
reservati ons in writi ng on the carrier's bill of lading if damage is detected, caused during transport (confi rmati on to
be sent to the carrier within 48 hours by registered mail with acknowledgement of receipt). In the event of a device
containing coolant that has been turned on its side, menti on your reservati ons in writi ng to the carrier.
• If the appliance suff ers a malfuncti on, do not try to repair the appliance yourself, contact a qualifi ed technician.
• Refer to the warranty conditi ons for details of the permitt ed water balance values for operati ng the appliance.
• Eliminati ng or shunti ng one of the safety devices automati cally voids the warranty, as does the replacement of parts
using parts not manufactured by ourselves.
• Do not spray insecti cide or any other chemical (infl ammable or non-infl ammable) in the directi on of the appliance,
as this may damage the body and cause a fi re.
• Heat pump, fi ltrati on pump and fi lter appliances are compati ble with all types of water treatment.
• For heat pump appliances or dehumidifi ers, do not touch the fan or insert a rod or your fi ngers through the grati ng
when the appliance is in operati on. The fan rotates at high speed and may cause injuries or even death.
• The electrical supply to the appliance must be protected by a dedicated 30 mA diff erenti al residual current protecti on
device, complying with the standards and regulati ons in force in the country where it is installed.
• Means for disconnecti on from the supply mains having a contact separati on in all poles that provide full disconnecti on
under overvoltage category III, must be incorporated in the fi xed wiring in accordance with the wiring rules.
• Before carrying out any operati ons, check that:
- The voltage indicated on the maker's plate of the appliance corresponds to the mains voltage,
- The power grid is adapted to the power requirements of the appliance, and is grounded.
- The plug (where applicable) is suitable for the socket.
• In the event of abnormal functi on or the release of odours from the appliance, turn it of immediately, unplug it from
its power supply and contact a professional.
• Before any interventi on on the appliance, ensure that the latt er is switched off and disconnected from the power
supply, in additi on to any other equipment connected to the appliance, and that the heati ng priority (where
applicable) is deacti vated.
• Do not disconnect and reconnect the appliance to the power supply when in operati on.
• Do not pull on the power cord to disconnect it from the power supply.
• Do not handle the electrical elements with wet hands.
• Clean the terminal board or the power supply socket before connecti on.
• For any component or sub-assembly containing a batt ery: do not recharge or dismantle the batt ery, or throw it into
a fi re. Do not expose it to high temperatures or direct sunlight.
• In stormy weather, unplug the appliance to prevent it from suff ering lightning damage.
• Do not immerse the appliance in water (with the excepti on of cleaners) or mud.
• Do not discharge R410A or R407C fl uid into the atmosphere. These are fl uorinated greenhouse eff ect gases, covered
by the Kyoto Protocol, with a Global Warming Potenti al (GWP) = 1975 for R410A or 1653 for R407C - (Directi ve EC
842/2006).
• According to French decree No. 2007-737, if the appliance has more than 2 kg of refrigerant gas (refer to manufacturer
specifi cati ons), the cooling circuit must be checked for leakage at least once a year. This operati on must be carried
out by a certi fi ed cooling appliance specialist.
Additi onal recommendati ons in relati on to the Pressure Equipment Directi ve (PED-97/23/EC)
Installati on and maintenance
The unit may not be installed close to combusti ble materials, or the air duct inlet of an adjacent building .
With some devices, it is essenti al to fi t protecti on grids if the unit is installed in an area with uncontrolled access.
During installati on, troubleshooti ng and maintenance, pipes may not be used as steps: the pipe could break under the weight,
spilling refrigerant and possibly causing serious burns.
When servicing the appliance, the compositi on and state of heat carrying fl uid must be checked, as well as the absence of any
refrigerant.
During the annual unit sealing test in accordance with applicable legislati on, the high and low pressure switches must be
checked to ensure that they are securely fastened to the coolant circuit and that they cut-off the electrical circuit when tripped.
During maintenance work, ensure there are no traces of corrosion or oil around cooling components.
Before beginning work on the cooling circuit, stop the device and wait for a few minutes before fi tti ng the temperature and
pressure sensors. Some elements such as the compressor and piping may reach temperatures in excess of 100°C and high
pressures with the consequent risk of severe scalding.
Troubleshooti ng
All soldering work must be carried out by a someone qualifi ed to do so.
Replacement pipes must always be made of copper in compliance with standard NF EN 12735-1.
Leak detecti on, pressure test:
- never use oxygen or dry air, risk of fi re or explosion,
- use dry nitrogen or the mixture of nitrogen and refrigerant indicated on the informati on plate,
- the test pressure for both the high and low pressure circuits must not exceed 42 bar (for R410A), 20 bar and 15 bar (for
R407C) in the case the device is equipped with the opti onal pressure gauge.
The high pressure circuit pipes are made of copper and have a diameter equal to or greater than 1''5/8. A certi fi cate as
indicated in §2.1 in compliance with standard NF EN 10204 will be requested from the supplier and fi led in the facility's
technical documentati on.
Technical data relati ve to the safety requirements of the various applicable directi ves must be indicated on the informati on
plate. All this informati on must be recorded in the unit's installati on manual, which must be kept in the technical fi le of the
unit: model, code, serial number, maximum and minimum OT, OP, year of manufacture, EC label, manufacturer's address,
refrigerant and weight, electrical parameters, thermo-dynamic and acousti c performances
Recycling
This symbol means that your appliance must not be thrown into a normal bin. It will be selecti vely collected for the
purpose of reuse, recycling or transformati on. Any substances it may contain which are potenti ally dangerous to the
environment shall be eliminated or neutralised.
Request informati on on recycling procedures from your retailer.