Priority Switches; Chime Switches - Bosch PLENA PLN-6AIO240 Installation And Operating Manual

Plena all-in-one system
Table of Contents

Advertisement

Plena All-in-One System
Number Item
48
Telephone/Emergency level
adjustment
55
Ducking level
7.1.1

Priority switches

Two switches (26) to set the Priority of inputs 1 to 6. The Telephone/Emergency input has
highest priority and always overrides all other inputs:
Switch setting
00
01
10
11
Table 7.1: Priority switches settings
7.1.2

Chime switches

Two switches (27) to select the chime on input 1 for a PLE-1CS or PLE-1SCS. The PLN-6CS
call stations have their own chime selector:
Switch setting
00
01
10
11
Table 7.2: Chime switches settings
Bosch Security Systems B.V.
Description
Adjusts the output level for the Telephone/Emergency signal applied to
inputs (46) and/or (47). This adjustment does not change the sensitivity
of the input gate (VOX).
Attenuates the music level from the internal music source or Music
inputs 1-3 when the priority mute function is activated.
The ducking attenuation is adjustable in the range 0 to -60 dB.
Priority
Serial: 1 > 2 > 3 > 4 > 5 > 6
Block
Override
Mix
Chime
No chime
1-tone chime
2-tone chime
4-tone chime
Installation and Operating Manual
Configuration | en
Remark
Input 1 has highest
priority.
Input 6 has lowest
priority.
The first activated input
gets priority.
Other inputs are muted
(blocked).
The last activated input
gets priority.
The other inputs are
overridden.
No priority.
All inputs are mixed.
Frequency
554 Hz
554/440 Hz
294/392/495/588 Hz
2014.09 | V1.2 |