Set the system security level (1 ~ 5) to be used for User verification. Please see the section "Level
(Security Level) in "Chapter 2 2.2.1 Enrollment options" to learn about security level. This menu is to set
the "system security level", and the "personal security level" can be individually set when enrolled or by
the menu "Edit User" (Refer to "Chapter 2 5.1 Edit User").
HCD Level
The Hand Vascular Pattern Recognition technology applied to the VP-II X can recognize human or non-
human materials. The decision level can be adjusted using this menu. The range is from 1 (most strict) to
3, or off (disabled).
Level 1: HCD applied for both enrolment and verification and is the most strict level. At this level only a
human hand can be enrolled and verified.
Level 2 and 3: HCD applied for enrolment only, not for verification. Off: HCD function disabled.
Retry Number
This sets the number of times the system retries if a hand verification fails, the default is 2, it can be
adjusted from 2 to 5 times.

2.4 Door Settings

The VP-II X system is capable of controlling doors with its controller without using a PACS (Physical
Access Control System). The following menu is to set or change the parameters required to control a
door.
Manager Menu > 3. System Settings > 5. Door settings
Controller
This is to select a controller being used for door control. The VP-II XG is selected as the controller,
additional controller options will be added in future upon availability. Select "None" if no controller is used.

2.4.1 VP-II XG (Door Controller)

The VP-II X can control an electric door-lock through the VP-II XG door controller. The VP-II XG is
separately provided and is connected to the VP-II X via RS232 (or RS485; an optional RS485 driver
board needs to be installed at both VP-II X and XG to use RS485 interface). The VP-II XG has a relay
output to connect an electrical lock and digital input ports for door status monitoring and exit button
interface.
Open Time
28