Specifications - Extech Instruments MA160 User Manual

True rms 200a ac/dc open jaw clamp meter
Table of Contents

Advertisement

6. Specifications 
ELECTRICAL SPECIFICATIONS 
Accuracy is given as ± (% of reading + least significant digits) at 23
<80%. Accuracy is specified for a period of one year after calibration. 
 
Function 
AC Current
 
DC Current
 
AC Voltage
 
DC Voltage
 
Resistance
 
Continuity
 
Diode
 
Shop for Extech products at:
Range 
Resolution
200.0 A 
0.1A 
TRMS, Frequency Response 50 to 60Hz 
200.0A 
0.1A 
DC Zero function in use 
6.000V 
0.001V 
60.00V 
0.01V 
600.0V 
0.1V 
750V 
1V 
True RMS voltage applicable to 10%~100% of the range 
Input Impedance: ≥ 10MΩ; Frequency response 40~400Hz 
6.000V 
0.001V 
60.00V 
0.01V 
600.0V 
0.1V 
1000V 
1V 
Input Impedance: ≥ 10MΩ 
600.0Ω 
0.1Ω 
6.000kΩ 
0.001kΩ 
60.00kΩ 
0.01kΩ 
600.0kΩ 
0.1kΩ 
6.000MΩ 
0.001MΩ 
60.00MΩ 
0.01MΩ 
600.0Ω 
0.1Ω 
Less than 10Ω beeper sounds. 10Ω to 100Ω undetermined. Greater than 100Ω 
beeper off (OL displayed). Open circuit voltage approx. 1.2V 
6.000V 
0.001V 
Open Circuit Voltage : Approx. 3.3V 
19
ShopExtech
C ±5
C with relative humidity 
Accuracy (reading) 
± (2.5% + 5 digits) 
± (2.5% + 5 digits) 
± (1.2% + 5 digits) 
± (1.2% + 3 digits) 
± (1.5% + 5 digits) 
± (0.8% + 3 digits) 
± (1.0% + 5 digits) 
± (1.2% + 2 digits) 
± (1.0% + 2 digits)
± (1.2% + 2 digits)
± (1.5% + 5 digits)
‐‐‐‐‐ 
0.5 to0.8V 
MA160‐en‐GB_V1.0   10/15 
1.888.610.7664
.com
'OL' Protection 
200A 
200A 
1000V DC 
750V AC 
1000V DC 
750V AC  
 
1000V DC 
750V AC 
1000V DC; 750V AC 
1000V DC; 750V AC 