4-1.
Equipment
Required
Oscilloscope
Tektronix
2465
or
equivalent (with
bandwidth
of
350
MHz)
NTSC/PAL
component
signal
generator
Tektronix
TG2000
+AVG1
(option
module)
+AWVG1
(option
module)
or
equivalent
Monoscope
signal
generator
ShibaSoku
TP22AX
or equivalent
VG
(programmable
video
signal
generator)
VG854
or equivalent
Frequency
counter
Advantest
TR5821
AK
or equivalent
Digital
VOM
Advantest
TR6845
or equivalent
Slide induction
transformer
High
tension voltmeter
DC
power
supply
Ammeter
Luminance
meter
Minolta
CA-100
or
equivalent.
If
the
Minolta
CA-100
is
not
available,
perform
the
measurement
by
visual inspection
by comparing
the
monitor
that
has already
been
adjusted
earlier
with
the
monitor
that
you want
to
adjust.
Note
Start
the following
adjustments 5
minutes
after
the
main
power
is
turned
on.
PVM-9L2
4-1