Section 3
Safety Related
Adjustment
This
section explains the
adjustment procedure
when
safety related
component(s)
is
replaced.
Perform
the
following adjustment
when
the safety related
component(s)
is
replaced.
[Preparation]
Equipment Required
Oscilloscope
Tektronix
2465
or
equivalent (with
bandwidth
of
350
MHz)
NTSC/PAL
component
signal
generator
Tektronix
TG2000
+AVG1
(option
module)
+AWVG1
(option
module)
or equivalent
Monoscope
signal
generator
ShibaSoku
TP22AX
or equivalent
VG
(programmable
video
signal generator)
VG854
or equivalent
DC
power
supply
Digital
VOM
Advantest
TR6845
or equivalent
Slide induction
transformer
Electrostatic
Voltmeter
High
tension
voltmeter
Ammeter
Luminance
meter
Minolta
CA-100
or equivalent
If
the
Minolta
CA-100
is
not
available,
perform
the
measurement by
visual inspection
by
comparing
the
monitor
that
has already
been
adjusted
earlier
with
the
monitor
that
you want
to adjust.
I
Note
I
Start
the
following adjustments
after
5 minutes have
passed
after
the
main power
is
turned
on.
When
the parts
(with a
B
mark
on
the
circuit
diagram)
shown
below
are replaced,
confirm
the
matters described
in
items 3-1
and
3-2
shown
below.
D
board
(HV
protector
circuit)
a
D504, D516, D1518, D1520, IC1508, IC1509,
Q503, Q504, Q505, Q506, Q1523, Q1524, Q1525,
R522, R523, R524, R526, R1573, R1575, R1577,
R1580, R1581, R1582, R1583, R1584, R1593,
R1594, R1598, R1599,
R1620
D
board (IK
protector
circuit)
a
D504, D516, D1519,
IC1509,
Q503, Q504, Q505,
Q506, Q1522, R522, R523, R524, R526, R1574,
R1576, R1578, R1585, R1586, R1587, R1588,
R1589, R1590, R1591, R1592,
R1620
3-1
.
HhB
Voltage
Check
1.
Supply
the
power
source voltage of
130
Vac
to the
set
and
turn
ON
the
power.
2.
Connect
the
480/601
all
black
signal to the
input
and
adjust the
BRIGHT
and
CONTRAST
of
the
User
Control of
the
main
menu
to
MIN.
3.
Check
that the
+B
voltage
is
38.5
to
41
.5
V.
-HB voltage
measurement
point
Between
C549
positive terminal
on
D
board and
GND
3-2.
Hold-down
Circuit
Connection
Check
1.
Supply
the
power
source voltage
of
120
Vac
to the
set
and
turn
ON
the
power.
2.
Connect
the
480/601
all
black
signal to the input
and
adjust the
BRIGHT
and
CONTRAST
of the
User
Control of
the
mcim
menu
to
MIN.
3
.
Check
that the
voltage
between
C
1
573
positive
terminal
on
D
board and
GND
is
3.80
V
or more.