2.12. CIS ADJUSTING MODE
In this mode, the position of Scanner motor is moved from the home
position up to the specified value. And document reading lamp is
turned on.
DIAG MODE
12:CIS ADJUST
[START/MEMORY] key
CIS ADJUST MODE
[START/MEMORY] key
The motor will move to the specified position and the reading lamp is lit on.
Press the [STOP] key to exit the mode.
2.13. SHARP CHART AGING
SHARP CHART is printed continuously.
DIAG MODE
Start by pressing the
[START/MEMORY] key
13:SHARP CHART AGING
Press the [STOP] key for interruption.
2.14. ASF AGING
The recording paper is fed continuously.
DIAG MODE
Start by pressing the
[START/MEMORY] key
14:ASF AGING
Press the [STOP] key for interruption.
2.15. IJP LIST MODE
Maintenance data of the printer is output.
MACHINE DOT COUNT
MACHINE PAGE COUNT
CARTRIDGE DOT COUNT
IDLE MAINTENANCE COUNT
INSTALL MAINTENANCE
COUNT
BEGIN OF JOB MAINTENANCE
COUNT
THRESHOLD MAINTENANCE
COUNT
POJ MAINTENANCE COUNT
SWATH START TEMPERA-
TURE
FUSE MEMORY VALUE
VPH ON TIME
CARTRIDGE CHANGE COUNT
JAM COUNT
NOZZLE CLEAN COUNT
CALIBRATION ENVIRONMENT
TEMPERATURE
CALIBRATION PRINT HEAD
TEMPERATURE
TEMPERATURE MODE
DIAG MODE
Start by pressing the
[START/MEMORY] key
15:IJP LIST MODE
SHARP CHART AGING
PRINTING
P.1
ASF AGING
Machine total dot count
Machine total page count
Cartridge-by-cartridge dot count
Maintenance information
Maintenance information
Maintenance information
Maintenance information
Maintenance information
Temperature control information
Cartridge information
Cartridge information
Cartridge replacement count
Jam count
Nozzle cleaning count
Environmental temperature infor-
mation
Cartridge temperature informa-
tion
Temperature control information
PRINTING
2.16. LIFE MODE
MACHINE PAGE COUNT is displayed.
DIAG MODE
16:LIFE MODE
Press the [STOP] key to exit the mode.
• LIFE MODE can also be checked by the following operation.
STAND-BY state
2.17. LIFE CLEAR MODE
MACHINE DOT COUNT and MACHINE PAGE COUNT are cleared.
DIAG MODE
17:LIFE CLEAR MODE
2.18. SECURE PASS LIST
Print the SECURE PASS LIST.
DIAG MODE
18:SECURE PASS LIST
2 – 5
UX-B800A
Start by pressing the
MACH.COUNT=0123456789
[START/MEMORY] key
FUNKTION
Press
Start by pressing the
[START/MEMORY] key
Start by pressing the
[START/MEMORY] key