3.3.4 ScanReader Interface (Option)

Reading
Pad
Cable Colors
Green
Red
Black
Fig. 3.9 ScanReader Connections

3.3.5 RS232 Local Computer Connection

WEBC2100
Fig. 3.10 RS232 Local Computer Connections
Note.
A USB Comms lead driver is required when using WEBC2100 –
download from
On battery or renewable energy versions, do not leave an RS232 connection plugged in or wired
with voltages applied unnecessarily. Such voltages result in far higher power consumption from
the battery or backup source, limiting battery / backup life.
The serial port connection shares the same physical port as the MODBUS connection so
(depending on cable design) it may be necessary to disconnect the MODBUS connection
temporarily to enable configuration of AquaMaster3.
OI/FET200–EN Rev. I
Red
Black
+V
Data
0V
Part No
USB
Connector
www.ftdichip.com/FTDrivers.htm
Part No.
WABC2104 /05, /10, /20, /30/ xx = cable length
3-Wire Transponder Connection
B
C
7 Pin MIL Connector
Pin
A
B
C
D
E
F
G
3 Electrical Installation
A
F
G
E
D
Function
Not used
RI
CTS
RTS
RXS
TXS
0 V
19