Class A
Press and hold IN button to retract
To stop the room during operation, release the
button.
When the room has retracted completely, it
will stop automatically.
After the room has been retracted, refasten the
safety travel strap.
Troubleshooting - Problems
Retracting the Room
Set the Park Brake if the red Park Brake light
flashes while pressing the Retract button.
Green light will flash error code
Reset Button (push with
toothpick or plastic rod)
If an error is detected on your DigiSync Room
Slide System, the green LED on the left side of
the control panel will blink an error code. If an
error code appears, see the Error Codes chart on
page 13-5 to determine the problem. The error
code must be cleared prior to operating the room.
To clear the error, press the "RESET" button.
Before operating the room after an error has been
detected, check for obvious faults such as
obstructions prior to trying to operate the room
again. If the error code appears again, the room
will need to be retracted using either the manual
retraction method or the fully manual method.
Both methods listed below are intended as a
means to retract the room to prepare the coach for
travel to the nearest authorized Service Center.
To retract the room after an error is detected,
you override the synchronization programming
and operate the room in the Manual Mode.
Manual Mode:
Manual Mode lets you individually move the
two room arms by pressing the IN and OUT
buttons on the control pad. This mode can be used
only if there is not a motor failure or full
electrical system failure. To override the encoder
and enter the Manual Mode, press and hold the
RESET button until the two LEDs begin to flash.
While in the Manual Mode each of the two,
room slide arms are activated by pressing and
holding the IN and OUT buttons. The OUT
button will retract the front arm. The IN button
will retract the back arm. Both IN and OUT
buttons may be held down at the same time to
simultaneously activate both arms to retract the
room. If one side of the room gets ahead of the
other, release that button until the other arm
catches up. The current limiting feature of the
control still functions in the Manual Mode so
each side can be fully retracted until it stops.
CAUTION
Never let one side get more than 2 inches
(50 mm) ahead of the other while
retracting.
Once the room has been retracted, the control
will return to the automatic mode after 60
seconds. You can manually return to automatic
mode by pressing the reset button.