Rj-45 Module Connectors - Cisco Nexus 7702 Hardware Installation Manual

Hide thumbs Also See for Nexus 7702:
Table of Contents

Advertisement

Switch Specifications
Transceiver Type
1000BASE-SX
1000BASE-LX
1000BASE-ZX
1000BASE-T
14 Extended (EXT) temperature range is 23 to 185°F (-5 to 85°C)

RJ-45 Module Connectors

The RJ-45 connector connects Category 3, Category 5, Category 5e, Category 6, or Category 6A foil twisted-pair
or unshielded twisted-pair cable from the external network to the following module interface connectors:
• Supervisor modules
• Fabric Extenders (Cisco Nexus 2232PP, 2232TM, 2232TM-E, 2248PQ, 2248TP, and 2248TP-E FEXs)
To comply with GR-1089 intrabuilding, lightning immunity requirements, you must use a foil twisted-pair
Caution
(FTP) cable that is properly grounded at both ends.
Part Number
GLC-SX-MMD
GLC-LH-SMD
GLC-ZX-SMD
GLC-T
SFP-GE-T
◦ CONSOLE port
◦ MGMT ETH port
◦ 100/1000 downlink ports
Cisco Nexus C2348UPQ FEX
• 1000/10000 downlink ports
Cisco Nexus C2348TQ-10GE FEX
• 100/1000/10000 downlink ports
Digital Optical
Operating
Monitoring Support
Temperature
14
Yes
EXT
5
Yes
EXT
6
No
COM
6
COM
5
EXT
Cisco Nexus 7702 Hardware Installation Guide
RJ-45 Module Connectors
Storage
Temperature
–40 to 185°F (–40
to 85°C)
105

Advertisement

Table of Contents
loading

Table of Contents