Trouble Shooting; Error Codes - Samsung RC090MHXEA Installation Manual

Rc-mhxga/rc-mhxea series air to water heat pump mono outdoor unit
Hide thumbs Also See for RC090MHXEA:
Table of Contents

Advertisement

Trouble shooting

• Incorrect handling of thermostat, safety valve or other valves may lead to tank rupture. When servicing the unit
follow instructions carefully:
WARNING
• Always turn off main power supply when water supply is being shut off.
• Test the free operation of the safety valve regularly by opening the valve ensuring the water flows freely.
• Electrical connection and all servicing of the electrical components should only be carried out by an authorized
electrician.
• Fitting and all servicing of plumbing fixtures should only be carried out by an authorized installer.
• When replacing the thermostat, safety valve or any other valve or part supplied with this unit, use only approved
parts of the same specification.

Error codes

If the unit has some problems and does not work normally, error code is shown on the OUTDOOR UNIT main PBA or LCD
of the wired remote controller.
Display
101
CONTROL KIT / OUTDOOR UNIT wire connection error
162
EEPROM Error
201
CONTROL KIT/OUTDOOR UNIT communication error (Matching error)
202
CONTROL KIT/OUTDOOR UNIT communication error (3 min)
203
Communication error between INVERTER and MAIN MICOM (6 min)
221
OUTDOOR UNIT temperature sensor error
231
Condenser temperature sensor error
251
Discharge temperature sensor error
320
OLP sensor error
403
Detection of OUTDOOR UNIT compressor freezing (During cooling operation)
Protection of OUTDOOR UNIT when it is overload (during Safety Start, Normal
404
operation state)
416
Discharge of a compressor is overheated
419
OUTDOOR UNIT EEV operation error
425
Power source line missing error (only for 3-phase model)
440
Heating operation blocked (outdoor temperature over 35°C)
441
Cooling operation blocked (outdoor temperature under 9°C)
458
OUTDOOR UNIT fan1 error
461
[Inverter] Compressor startup error
462
[Inverter] Total current error/PFC over current error
463
OLP is overheated
36
EHS mono_RC***MHXGA_IM_E_34411A(3).indd 36
Explanation
Error Source
CONTROL KIT,
OUTDOOR UNIT
CONTROL KIT
CONTROL KIT,
OUTDOOR UNIT
CONTROL KIT,
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
2012-11-26 오후 3:02:01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents