CLEANING and MAINTENANCE
Make sure the gas valve knob is in the "OFF" position. Wait at least five (5) minutes before
starting maintenance. Fireplace must be cold before starting maintenance.

VENTING SySTEM

A qualified agency should examine the venting system annually.

CLEANING GLASS

Clean the tempered glass periodically. Condensation will sometimes form on the glass during
a cold startup. This is normal for all gas fireplaces. This condensation often attracts dust and
lint to the surface of the glass. The initial paint curing of the appliance can also leave a slight
film on the glass.
You should clean the glass after the first two weeks of use. After that, you should clean the
glass no more than two or three times a season. Use a mild glass cleaner to clean the door.
Do not use abrasive cleaners. They will damage the glass surface.
PILOT AND BURNER FLAMES
Visually check pilot and burner flames periodically. Refer to Figure 58
for typical burner flame appearance. Refer to Figure 57 for typical pilot
flame appearance.

FIREBOx CLEANING

1. Carefully remove log set, and embers (rock wool) from combustion
chamber.
2. Vacuum burner compartment thoroughly.
3. Vacuum or brush with soft brush any dust off logs.
4. Remove any lint from main burner and pilot.
5. Carefully replace log set and embers in their correct positions. Refer
to Page 35
6. Replace door (if it has been removed).
7. Relight pilot. Page 41
8. Turn on main burner.
Figure 58 -
Burner Flame Appearance
4
LG566
log flames
Thermocouple
Figure 57 -
Pilot Flame
FP2070
pilot flame
Make sure clearances to com-
bustibles leave room for main-
tenance and service.
Carefully reassemble and
reseal fireplace properly after
any cleaning or servicing.
Thermopile
FP2070
53D0419