ABB DCS800 Hardware Manual page 82

Dcs800 drives (20 to 5200 a)
Hide thumbs Also See for DCS800:
Table of Contents

Advertisement

82
X1:1
81-270V
-
2
25-90V
TG
3
8-33V
+
4
5
R9
6
7
PS5311
8
SDCS-IOB-3
-
S1
X3:1
1 2
+
500
2
-
3
3 4
+
4
-
5
5 6
+
6
-
7
7 8
+
8
-
9
9 10
+
10
~
11
~
12
X4:1
2
3
4
100
47.5
5
100n
6
0V
7
8
9
1 2
100
10
3 4
11
12
S10
X5:1
4 5 6
+24V
2
3
10 11 12
+24V 7 8 9
4
5
16 17 18
+24V 131415
6
7
Sense Power +
8
Sense GND
9
10
➀ total smoothing time ≤2 ms
➁ -20...0...+20 mA by setting S1
➂ 4...20 mA by ➁ + Software function
➃ -1...0...-1 V by setting S2/S3 (CMR ±10 V)
-2...0...-2 mA by setting S2/S3 + S1 (CMR ±10 V)
➄ designated for PT100 evaluation per firmware and
hardware
➅ If the input is used for tacho feedback and the tacho
voltage needs to be scaled, the board PS5311 must be
ordered separate. If this input is used for feedback
signals, there is a need for additional margin for
overshoot measurement. This margin is set by software
and results e.g. in the 8 to 33 volts at PS5311.
* short circuit proof
Technical data
X2:3
4
X2:3
5
X2:4
6
7
8
SDCS-CON-x
100k
100k
1n
100k
100k
1n
S2
x10
x10
S3
12
14
S1
13
11
100
100
47.5
100n
0V
0V
+/- I-act
x
3 V = I NDC
R110
+10V
0V
-10V
1.5 mA
S5
5 mA
0V
S10
ChA +
1 2 3
ChA -
ChB +
ChB -
ChZ +
ChZ -
V17
Power-
Source
GND
S4
iob3x2 e.dsf
➆Residual current detection is selected as default. The jumpers S1:11-12 and S1:13-14 are set, inputs X3:9 and X3:10
and jumper S1:9-10 must not be used and inputs X3:11 and X3:12 serve as input for the current signal taken from a
current transformer. This detection is based on a sum current transformer where the secondary is connected through a
diode bridge to 100 W resistor . Voltage will appear across the resistor, if the sum of the 3-phase current is not zero. In
case AI4 should be used for a different purpose, use the inputs/jumpers accordingly and take the block diagram as a
help.
Restrictions using jumper S1, S2 or S3:
The selection for the burden resistor across the input terminals can be done independent from S2 or S3 settings for inputs
AITAC, AI1, AI2, AI3 and AI4.
If the gain is set to 10 by using S2 or S3 and the 500 W burden resistor is activated, the input signal level is changed to -2
mA...0...+2 mA.
For input AI4 there are the following configurations available:
- input range "20mA" , or
- input range "10V", or
- earth fault monitoring by Isum not equal to zero via X3:11 and X3:12
3ADW000194R0201 DCS800 Hardware Manual e b
Note:
When the SDCS-CON-4 control board with the SDCS-IOB-3 I/O
board is installed, analogue tacho input at SDCS-CON-4 should
be used:
Terminals X3:, X4: and X5: on the SDCS-CON-4 must not be used
Resolution
Input/output
[bit]
Software
AITAC
-10...0...+10 V Firmware ±20 V ➀➁➂➅
15 + sign
AI1
-10...0...+10 V Firmware ±20 V ➀➁➂
15 + sign
3.3 ms
AI2
-10...0...+10 V Firmware ±40 V ➀➁➂➃➄
15 + sign
3.3 ms
AI3
-10...0...+10 V Firmware ±40 V ➀➁➂➃➄
15 + sign
10 ms
AI4
-10...0...+10 V Firmware ±40 V ➀➁➂
15 + sign
10 ms
-10...0...+10 V Firmware ≤ 5 mA*
11 + sign
AO1
-10...0...+10 V Firmware ≤ 5 mA*
11 + sign
AO2
analogue
-10...0...+10 V R110
R
i
Encoder supply
5 V
12 V / 24 V
Scaling
Com-
values
by
mon
Hardware
mode
range
Power
≤ 5 mA* gain: 0.5...5
= 3 Ω
≤ 5 mA* for external use
≤ 5 mA* e.g. reference pot.
1.5 mA
5 mA
Remarks
Inputs not isolated
Impedance = 120 Ω , if selected
max. frequence ≤ 300 kHz
≤ 250 mA *
Sense lines for GND and supply to
≤ 200 mA *
correct voltage drops on cable (only if
5V/12V enc. is in use)
.
Remarks
Curr. source for
PTC or PT100

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents