Promax FA-405 Manual page 75

Programmable power supply
Table of Contents

Advertisement

Available languages

Available languages

USER'S MANUAL FA-405
Explain:
The power supply will set the desired value of output voltage when the
command is received.
Example: SV 12.34
Set output voltage to 12.34V
SU
Function: Set voltage limit.
SU xx
Syntax:
x is a number between 0 and 9.
Explain:
The power supply will set desired up-limit value of the voltage when the
command is received.
Example: SU 20
Set voltage limit to 20V
SI
Function: Set current limit.
Syntax:
SI x.xx
x is a number between 0 and 9.
Explain:
The power supply will set desired up-limit value of the current when the
command is received.
Example: SU 1.25
Set current limit to 1.25A
SP
Function: Set power limit.
Syntax:
SP xxx
x is a number between 0 and 9.
Explain:
The power supply will set desired up-limit value of the power when the
command is received.
Example: SP 100
Set power limit to 100W
The power setting changes the current limit only, the voltage limit will remain
12/2003
unchanged.
Page 31