USER'S MANUAL FA-405
Explain:
When the message of D<cr> is sent to the power supply from computer,
the power supply will return the following message immediately
The contents consist of the uppercase D, and the numeral from 0 to 9.
Further details is described as follows:
When the uppercase D becoming the lowercase d means that the status
is in the setting of the -% mode.
Q
Function: Display the present value at +% or -% mode.
Syntax:
Q<cr>
Explain:
When the message of Q<cr> is sent to the power supply from computer,
the power supply will return the following message immediately
The contents consist of the uppercase B, and the numeral 0 or 1. Further
details is described as follows:
SB+
Function: To add one unit to the present setting of +%.
Syntax:
SB+<cr> HEX = 53 42 2B 0D
Explain:
When the message of SB+<cr> is sent to the power supply from
computer, the power supply will add one unit to the present setting of +%
immediately
Example: The present +% value is at 105, after the command is sent from
computer, the +% value is at 106.
12/2003
Dddd<cr>
4 characters totally +CR/LF
ddd = The present -% value, the unit: %
HEX = 51 0D
Qqqqqqq<cr>
7 characters totally +CR/LF
Whether the first q is at -% mode? 0: No 1:Yes
Whether the second q is at +% mode? 0: No 1: Yes
Page 29