KOD
Function: Set the Relay status to OFF.
Syntax:
KOD<cr>
Explain:
When the message of KOD<cr> is sent to the power supply from
computer, whatever the relay status is, the relay of power supply will be
set to OFF immediately.
EEP
Function: Save the present status to the EEPROM.
Syntax:
EEP<cr> HEX = 45 45 50 0D
When the message of EEP<cr> is sent to the power supply from
Explain:
computer, the power supply will be save the present setting value to
EEPROM immediately.
B
Function: To obtain +% value.
Syntax:
B<cr> HEX = 42 0D
When the message of B<cr> is sent to the power supply from computer,
Explain:
the power supply will return the following message immediately
The contents consist of the uppercase B, and the numeral from 0 to 9.
Further details is described as follows:
When the uppercase B becoming the lowercase b means that the status
is in the setting of the +% mode.
D
Function: To obtain -% value.
Syntax:
D<cr>
Page 28
HEX = 4B 4F 44 0D
Bbbb<cr>
bbb = The present +% value, the unit: %
HEX = 44 0D
4 characters totally +CR/LF
USER'S MANUAL. FA-405
12/2003