14. Preparation

a) Calibrate build bed

1
• Press the control knob in < Info
screen > to enter < Main Page >.
4
• Adjust 3 screws under build bed
to adjust the gap between build
bed and nozzle until built plate is
lying flat.
• Gap distance should be between
0.1 and 0.3 mm (i.e. use A4
paper as a measurement tool).
Nozzle must not touch build
plate!
2
• In < Main > menu select
< Prepare > .
5
Prepare
First point
Second point
Third point
• Return to < Prepare > menu.
• Enter < Level bed > menu and
select < First point >.
• Ensure
during
adjustment, that the distance
between nozzle and build bed
should be same each time.
Otherwise build bed is uneven
and print objects may not adhere
to it properly.
3
• Select < Auto home >.
6
• Repeat STEPS 1-4 for second
and third points (calibration
sequence and movement path of
nozzle are shown).
build
bed
21