Town & Country Fireplaces TC30 Installation Manual

Series d modular direct vent fireplace

Advertisement

INSTALLATION MANUAL
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING:
If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
FOR YOUR SAFETY
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WhAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier call
the fire department.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Visit www. townandcountryfireplaces.com for the most recent version of this manual
100817-44
TC30
INSTALLATION
MANUAL
MODEL TC30
SERIES D - Version 2
MODULAR DIRECT VENT
FIREPLACE
TC30_D.Ver 2
5056.429D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TC30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Town & Country Fireplaces TC30

  • Page 1 This appliance is not convertible for use with other gases, unless a certified kit is used. MODEL TC30 This appliance is suitable for installation in a SERIES D - Version 2 bedroom or bed sitting room.
  • Page 2: Table Of Contents

    TC30 Minimum Combustible Framing Vent Offset Chart ..........32 Dimensions ............9 Firebox Panels Installation ........33 TC30 Steel Stud Framing Kit .......11 Finishing Touch Trim Kit Instructions ....34 Fixed Lintel ............13 Linking Remote Handset to the Fireplace ... 35 Hearth Extension ..........
  • Page 3: Caution

    This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 4: Important Note For The Commonwealth Of Massachusetts

    A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 5: Fireplace Dimensions

    3” ** MANTEL DEPTH 12” TOP OF LINTEL BAR 6 3/4” 1 1/2” FIREPLACE FRONT Figure 2: TC30 Mantle clearances. Minimum Clearances: CEILING Side standoffs ..........0 in. (0 mm) Back standoffs ..........0 in. (0 mm) MANTEL Top standoffs ..........0 in.
  • Page 6: Installation Requirements

    Figure 5: Accessing Figure 6: Handle. Figure 4: Safety barrier handle. screen. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 7: Top Standoffs

    (Figure 8). Due to high temperatures, do not locate this fireplace in areas of high traffic or near furniture or draperies. The minimum clearances from the fireplace to combustible surfaces must be adhered to and are shown in Figures 2 & 3. Figure 8: TC30 Common locations. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 8: Framing And Finishing

    LATION, PLASTIC VAPOR BARRIER OR GAS PLUMBING WITHIN THE STEEL STUD FRAMING ALL OTHER FRAMING CAN BE DONE WITH CONVENTIONAL LUMBER 47 3/8” 12” 47 3/8” 28 1/4” 40 3/8” 5 7/8” Figure 9: TC30 Framing kit dimensions. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 9: Tc30 Minimum Combustible Framing Dimensions

    87 1/2" FRAME RANGE 1/2" to 2 3/8" LINTEL Must allow for minimum 1/2 inch 47 3/8" gap for non-combustilbe board. NOTE: FIREPLACE SHOULD BE IN ITS FINAL LOCATION BEFORE FRAMING. Figure 10: TC30 Minimum Combustible Framing. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 10 NOTE: It is recommended to pre-drill mounting holes in the board prior to securing to the framing. This will prevent Figure 11: TC30 Non combustible board dimensions. the board from cracking. Non-combustible recessed installation detail...
  • Page 11: Tc30 Steel Stud Framing Kit

    TC30 Steel Stud Framing Kit Each Kit Contains: Figure 14: TC30 Framing kit parts. Item Description Screw, Teks #8 x 1/2” (Not Shown) Pkg 40 Stud, Sides Inner, 40 1/4” L Stud, Sides Outer, 40 1/4” L Stud, Center, 12” L Stud, Header Horizontal, 43 1/2”...
  • Page 12 Fasten the outer side studs (3) at the bottom using the base plates (7). Framing brackets 3. Attach the Assembled Frame to the Unit Figure 15: TC30 Framing brackets. • Align and secure the framing plates (8) to the frame so that they are in line with the framing brackets on the fireplace unit (Figure 15).
  • Page 13: Fixed Lintel

    The knock outs are for a future optional “TV KIT” which will allow a television to be mounted above the fireplace while having the heat from the fireplace re-directed to a vent which will be located above the TV. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 14: Hearth Extension

    Hearth Extention Bottom of replace Figure 21: TC30.D Hearth extension. Caution: While a hearth extension is not required and combustible floor- ing materials may be brought directly up to the fireplace, many materials (such as wood flooring) may not tolerate the radiant heat from this fire- place, resulting in discoloration, shrinking and cracking.
  • Page 15: Electrical

    (Figure 25) to the “ON” position. The switch igniter will start to spark. After a short delay, the pilot will light followed by the Wall switch main burner. Module connector Interface board Junction box Figure 24: Valve assembly components. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 16: Wall Switch And Remote Control

    5056.429-D2 TC30-D ver2_100817-44...
  • Page 17: Selecting Natural Vent And Power Vent Modes

    Important Note: When switching between NV and PV, both the electrical power supply to the fireplace must be turned off and the backup batteries removed to properly re-set the module. Figure 28: Natural vent - Power vent switch. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 18: Home Automation

    Figure 30: Home automation side wiring diagram. NOTE: • Digital I/O must be connected to a dry contact relay. • Analog flame and light input through 0 - 10 volt DC signal scaled as follows: Low = 1 volt high = 10 volts 5056.429-D2 TC30-D ver2_100817-44...
  • Page 19: Gas Supply

    Propane Manifold pressure Min. Pressure 5.0" WC 12.5" WC (For purpose of input adjustment) Max. Pressure 13.9" WC 13.9" WC Manifold Pressure Maximum 3.5" WC 10" WC Minimum 1.6" WC 6.4" WC Figure 31: Gas testing ports. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 20: Venting

    See (Figure 35) & (Figure 36). For longer horizontal runs increase vertical rise appropriately. The rise and run must be constrained to the boundaries of the chart shown in (Figure 36). The horizontal run of vent must have a 1/4" rise for every 1 ft. of run towards the termination. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 21 Roof Termination Kit ..........TCVT.RTA Wall Shield/Ceiling Firestop ........TCVT.THIMA Roof Flashing, Adjustable ........TCVT.811FLADJ Roof Flashing, Flat ..........TCVT.811FLFLT Roof Flashing, Steep ..........TCVT.811FLSTP or any flashing that fits 11" pipe Figure 34: Vent system components. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 22 * Minimum height 52 7/16 from the floor to center of the opening with a maximum horizontal run of 34 5/16" using a 24" pipe. The height will need to be increased with a longer horizontal run. Figure 35: Wall vent terminal framing. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 23: Wall Termination Venting Chart

    90° elbow, or an equal combination of elbows, reduce horizontal vent run by 2 feet. Ensure vent pipe is properly supported. A minimum of 1 support every 4’ must be used. Figure 36: Wall termination venting chart. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 24: Roof Termination Venting Chart

    For each additional 90° elbow, or an equal combination of elbows, reduce horizontal vent run by 2 feet. Ensure vent pipe is properly supported. A minimum of 1 support every 4’ must be used. Figure 37: Roof terminal venting chart. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 25: Roof Termination Venting

    ROOF SUPPORT BRACKET to accommodate roof pitch. Attach the (TCVT.93915) brackets to the roof joists with nails or building screws. Tighten the band around the vent pipe and secure in place with Figure 39: Roof support bracket. screws. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 26 VERTICAL TERMINATION CAP (TCVT.9365) VENT PIPE MASTIC (UNDER STORM STORM COLLAR COLLAR) (TC42.90665) FLASHING Note: Adjustable for various roof pitches, from flat roof to 12/12 pitch roof. Figure 40: Roof terminal. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 27: Vent Terminal Clearance

    ** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149.1 Installation Codes, Note: local Codes or Regulation may require different clearances * for U.S.A. Installations follow the current National Fuel Gas Code, NFPA54/ANSI Z223.1 5056.429-D2 TC30-D ver2_100817-44...
  • Page 28: Vent Pipe Sealant

    Figure 44: Sealing with tape. All outer joints of the vent pipe must be sealed with the approved "High Temperature" self- adhesive aluminium tape provided. Wrap the tape completely around the joint and press firmly in place. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 29: Vent Restrictor Adjustment

    To adjust the restrictor: • Loosen the screw holding the restrictor. • Move the restrictor to its intended opening. • Re-tighten the screw. FULLY OPEN OPENING VENT RESTRICTOR 18" Figure 45: Restrictor wall and roof chart. CAUTION: The vent restrictor must be fully open when using the power vent Figure 46: Vent restrictor. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 30: Wall Shield/Ceiling Firestop Thimble

    Fire stop thimble. Figure 47: Figure 48: Wall terminal kit. Roof Termination Kit 16 1/2" VERTICAL TERMINATION CAP TCVT.9365 9" STORM COLLAR TC42.90665 WALL SHIELD / CEILING ROOF SUPPORT FIRESTOP BRACKET TCVT.THIMA TCVT.93915 Figure 49: Roof termination kit. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 31: Vent Pipe Dimensions

    48" PIPE ..46 1/4" 10 15/16" 9 1/2" TCVT.811X12ADJ 11 1/8" TCVT.811X _ _ 13 13/16" 12 9/16" 8 5/16" 1 5/16" 13 1/8" 7/16" 10 5/16" TCVT.811XLB45 15 7/8" TCVT.811XLB90 Figure 50: Vent pipe dimensions. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 32: Vent Offset Chart

    1 1/4” 1 1/4 “ 18 3/4" 12" PIPE 29" Adding an adjustable section to 18" PIPE 35" pipe will increase offset by 3" 24" PIPE 41" to 9 1/2" 48" PIPE 65" Figure 51: Vent offset chart. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 33: Firebox Panels Installation

    Firebox Panels Installation PARK AVE. hERRINGBONE 2 ............TCPN.30PAC2 TC30 PANELS MANhATTAN STACKED BRICK 2 ............. TCPN.30MCN2 MT. VERNON RED BRICK 2 ...............TCPN.30VRC2 BLACK PORCELAIN ................TCPN.770.C COFFEE BEAN BROWN PORCELAIN ........... TCPN.770CB.C MILAN 2 ..................... TCPN.30MILC2 TITANIUM .................... TCPN.770TI.C COPPER .....................TCPN.770CU.C...
  • Page 34: Finishing Touch Trim Kit Instructions

    4. Attach the top and bottom rails and adjust so mitres are even at the corners. 5. Place TC magnetic logo in bottom right corner. Larger magnets Top or bottom rail Side rails Figure 54: TC30 trim kit. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 35: Linking Remote Handset To The Fireplace

    If there is cross communication with another nearby fireplace causing the other fireplace to activate instead of the intended fireplace, repeat above procedure to automatically switch to another one of three available channels. PROGRAM BUTTON Figure 55: Town and Country wall switch. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 36 3. Press and release the on/off button (Figure 56) on the remote handset (within 60 sec.) 4. The wall switch will beep 3 times. 5. The remote handset is now linked/paired to the wall switch and is ready to activate the fireplace. ON /OFF Figure 56: Remote handset. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 37: Maintenance

    Viewing glass may be cleaned as necessary with fireplace glass cleaner. b) Exterior finish may be cleaned with mild soap and water. CAUTION: Do not use abrasive cleaners on glass or any other part of the fireplace. Do not clean glass when hot. Figure 57: Pilot light. 5056.429-D2 TC30-D ver2_100817-44...
  • Page 38: Tc30-D Replacement Parts

    TC30-D Replacement Parts (WhEN ORDERING, INCLUDE PART NUMBER & SKU WITh DESCRIPTION) ITEM DESCRIPTION PART NO. TC30 ................TC30.D2 ..........22030003 GLASS ASSM C/W GASKET ........GLAS.2066 FRAMING KIT............TC30. 9266-A PANEL SETS PARK AVE............TCPN.30PAC2 ..........22200009 MANHATTAN STACKED BRICK 2 ....... TCPN.30MCN ..........22200006 MT.
  • Page 39: Wiring Diagram

    Wiring Diagram 5056.429-D2 TC30-D ver2_100817-44...
  • Page 40: Rating Label

    *9 in./ 9 po. (229 mm) Maximum Mantel Extension / Allongement maximum du manteau *12 in./ 12 po. (305 mm) *See Installation Manual for more detail / Voyez des Directive de l’Installation pour plus détaux. Mantel Supports / Supports du manteau 4 in./ 4 po. (102 mm) JAN FEB MAR APR 2014 Vent Pipe / Déchargez le Tuyau 1.75 in./ 1.75 po. (45 mm) MAY JUN JUL AUG 2015 WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information, consult a qualified installer, service agency or the gas supplier. AVERTISSEMENT: Une installation, un réglage, une modification, une réparation ou un entretien mal effectué peut causer SEP OCT NOV DEC 2016 des dommages matériels ou des blessures. Voir la notice de l’utilisateur qui accompgne l’appareil. Pour de l’aide ou des renseignements supplémentaires, consultez un installateur, un technicien agréé ou le fournisseur de gaz. 200814 5056.429D 1-TC30-D 5056.429-D2 TC30-D ver2_100817-44...
  • Page 41 5056.429-D2 TC30-D ver2_100817-44...
  • Page 42 5056.429-D2 TC30-D ver2_100817-44...
  • Page 43 5056.429-D2 TC30-D ver2_100817-44...
  • Page 44 © 2017 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For technical support, please contact your retailer. Web site: www.townandcountryfireplaces.com 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada...

Table of Contents