ELECTRICAL CONNECTIONS

VULCAN-230V / VULCAN-120V
CONTROL UNIT
Motor cable
DX motor
YELLOW - GREEN
GND
GREY
COMMON
BLACK
OPENING
BROWN
CLOSING
m
WARNING: Always connect the earth cable to the
mains power earth system. Use the special fastom shown in
the figure, and a cable with a minimum cross sectional area
of 2.5 mm
2
VULCAN-24V
CONTROL UNIT
Motor cable
DX motor
BLUE
+
BROWN
-
SX

ENCODER CONNECTION

To connect the encoders please refer to the control unit manual.
m
WARNING: For the encoders to work properly it is
essential that the stoppers inside the case are installed
correctly.
m
ATTENTION: DO NOT use the motor cable channel for
the sensor cables.
m
ATTENTION: extensions of the cables must be made
only with a 4x0,22 shielded cable with polyethylene sheath
m
ATTENTION: connect the shielding braith sheath to the
common accessories. Check that the ground of the power
supply of the accessories is connected to the common
accessories.
SX motor
GND
COMMON
CLOSING
OPENING
SX motor
-
+
EMERGENCY UNBLOCKING
In the case of a power failure, the gate can be unblocked
mechanically by operating the motor.
Insert the supplied unblocking lever and rotate 180° clockwise.
Automation will be automatically restored the first time the motor
is operated.
- 12 -