Specifications; Available Constructions - Emerson 299H Instruction Manual

299h series pressure reducing regulators
Hide thumbs Also See for 299H:
Table of Contents

Advertisement

299H Series

Specifications

Specifications for 299H Series constructions are given below. Some specifications for a given regulator as it
originally comes from the factory are stamped on a nameplate located on the actuator upper casing.

available Constructions

Type 299H: Pilot-operated pressure reducing
regulator with a pilot integrally mounted to the
actuator casing.
Type 299HR: A Type 299H with a token internal
relief valve to relieve minor overpressure caused
by thermal expansion.
Type 299HS: Same as the Type 299H
with a Type VSX-2 slam-shut valve which
provides overpressure or overpressure and
underpressure protection.
Type 299HV: Same as the Type 299H
with a Type VSX8 slam-shut valve which
provides overpressure or overpressure and
underpressure protection.
Type 299HSR: Same as the Type 299HS with an
internal token relief valve.
Type 299HVR: Same as the Type 299HV with an
internal token relief valve.
Body Size and End Connection Styles
See Table 1
Maximum Operating inlet Pressure by Orifice Size
1/4 x 3/8 in. / 6.4 x 9.5 mm . . . . . . .175 psig / 12.1 bar
3/8 in. / 9.5 mm . . . . . . . . . . . . . . . .175 psig / 12.1 bar
1/2 in. / 13 mm . . . . . . . . . . . . . . . .175 psig / 12.1 bar
3/4 in. / 19 mm . . . . . . . . . . . . . . . .150 psig / 10.3 bar
7/8 in. / 22 mm
. . . . . . . . . . . . . . .125 psig / 8.6 bar
(5)
1 in. / 25 mm
. . . . . . . . . . . . . . . . .100 psig / 6.9 bar
(5)
1-3/16 in. / 30 mm
. . . . . . . . . . . 80 psig / 5.5 bar
(5)
Maximum Casing and Emergency Outlet Pressure
66 psig / 4.5 bar
Outlet (Control) Pressure Ranges
See Table 2
Maximum Set Pressure for Types 299HS and 299HV
16 psig / 1.1 bar
1. The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
2. For optimum performance, a pilot supply regulator may be installed in the pilot supply tubing between the main valve and pilot.
3. A pilot supply regulator or a P590 Series filter (only one may be used, not both) may be ordered with the Type 299H, but not both.
4. For in. w.c., use a pilot supply regulator if actual inlet pressure varies more than ±20 psi / ±1.4 bar and published accuracy is required.
5. This orifice size is not available for Types 299HS, 299HV, 299HSR and 299HVR.
6. Product has passed Emerson testing for lockup, relief start-to-discharge and reseal down to -40°.
2
Maximum Set Pressure for Slam-Shut Device
Minimum and Maximum Trip Pressure Ranges
Types VSX2 and VSX8 Sensing Line Connection
Pressure Control accuracy (Fixed Factor)(PFM)
Minimum Differential Pressure For Full Stroke
Control Line Connections
Temperature Capabilities
approximate Weight
Pressure Registration
(1)
Fixed Restriction Sizes
Options
(1)
(1)(2)
(1)
See Table 2
See Type VSX2 slam-shut Instruction Manual
D103695X012 or Type VSX8 slam-shut Instruction
Manual D103127X012.
1/4 NPT
±1%
of absolute control pressure
(3)
1.5 psid / 0.10 bar d
3/4 NPT
-20 to 150°F / -29 to 66°C
21 lbs / 10 kg
Internal, External or Dual Registration
See Figure 2
0.044 in. / 1.1 mm, Red (standard gain)
0.071 in. / 1.8 mm, Green (low gain)
0.082 in. / 2.1 mm, Blue (lower gain)
• Filter
: A P590 Series filter installed in the pilot
(3)
supply tubing between main body and pilot
• Filtered pilot supply regulator
supply regulator with integral 5 micron
Polyethylene filter
(1)
(1)(6)
: A Type 67CF
(3)(4)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

299hsr299hv299hvr299hr299hsFisher 299h series ... Show all