TABLE "A" PARAMETERS MENU -
Logic
min.
max.
0
0,1
0,1
1
1%
1%
0%
1%
1%
0
TABLE "B" LOGIC MENU -
Logic
Default De nition
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Téléchargé sur www.confort-electrique.fr
Default
De nition
Personal
Automatic Closing
180
40
Time
100
3
Opening delay time
100
3
Closing delay time
Time-to-clear traffic
180
40
light zone
99%
10%
Motor 1 torque
99%
10%
Motor 2 torque
99%
20%
Slow-down speed
99%
20%
Slow-down space
99%
50%
Pedestrian opening
129
0
Zone
Cross out
setting
used
ON
Automatic Closing
Time
OFF
ON
Opening Impulse lock
OFF
ON
Impulse lock TCA
OFF
ON
Impulse lock on closing
OFF
ON
Ram blow on opening
OFF
ON
Ram blow in closing
OFF
ON
2-step, 4-step logic
OFF
ON
3-step logic
OFF
ON
Pre alarm
OFF
Retrouvez tous les produits du fabricant BFT sur notre site internet www.confort-electrique.fr
INSTALLATION MANUAL
Description
Set the numerical value of the automatic closing time from 0 to 180 seconds.
Set the opening delay time for motor 1 relative to motor 2, between 0,1 and 100
seconds. Adjust the time lag so that the minimum distance between the leaves,
when both are moving, is 50 cm.
Impostare il ritardo di chiusura del motore 2 rispetto al motore 1, regolabile da
0,1 a 100 secondi. Adjust the time lag so that the minimum distance between
the leaves, when both are moving, is 50 cm.
Set the desired time-to-clear for the zone run through by tra c controlled by the
tra c light, in the range 1 to 180 seconds.
Set the numerical value of the motor 1 torque between 1% and 99%.
This parameter denotes sensitivity to the obstacle (couple=1 maximum sensitivity).
Set the numerical value of the motor 1 torque between 1% and 99%.
This parameter denotes sensitivity to the obstacle (couple=1 maximum sensitivity).
Imposta la percentuale della velocità di rallentamento tra 0% e 99% della velocità
normale.
N.B. il valore 0 non e ettua il rallentamento dei motori.
Set the slow-down percentage between 1% and 99% with respect to the com-
plete manoeuvre.
Set the partial opening percentage for motor 2.
Set the zone number between a minimum value of 0 and a maximum value of
129.
The zone number allows you to create groups of automated devices, each of which
answers to the Zone Master. Each zone can have only one Master. The Master of
zone 0 also controls the Masters and Slaves of the other zones.
Description
Activates automatic closing
Excludes automatic closing
The Start impulse has no e ect during the opening phase.
The Start impulse becomes e ective during the opening phase.
The Start impulse has no e ect during the TCA dwell period.
The Start impulse becomes e ective during the TCA dwell period.
The start impulse has no e ect during the closing stage.
The start impulse is e ective during the closing stage.
It pushes for approx. 2 seconds in closing direction before opening. This allows the electric
lock to be released more easily.
IMPORTANT - When no adequate mechanical backstops are installed, do not use this function.
Excludes the ram blow in closing.
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows
the solenoid lock to be released more easily.
IMPORTANT - When no adequate mechanical backstops are installed, do not use this function.
Excludes the ram blow in closing.
Enables 2-step logic (prevails over "3-step logic").
Enables 4-step logic when the 3-step logic is set to OFF.
Enables 2-step logic
(prevails over "3-step
logic").
Enables 4-step logic
when the 3-step logic
is set to OFF.
The blinker comes on about 3 seconds before the motor starts.
The blinker comes on at the same time as the motor starts.
Retrouvez tous les produits du fabricant BFT sur notre site internet www.confort-electrique.fr
A start impulse has the following e ects:
2 steps
3 steps
closed
opens
opens
on closing
open
closes
closes
on opening
stop + TCA
after stop
opens
opens
4 steps
opens
stop
closes
stop + TCA
opens
LIBRA-C-LX - 17