Download Print this page

Advertisement

Available languages

Available languages

8
027908
4 2 3 8 8 7
CONTROL PANEL
CUADRO DE MANDOS
ORIGINALE
N26683
Caution! Read "Warnings" inside carefully! Atención¡ Leer atentamente las "Advertencias" en el interior!

Advertisement

loading
Need help?

Need help?

Do you have a question about the SIRIO CBA 230 INV and is the answer not in the manual?

Questions and answers

Summary of Contents for BFT SIRIO CBA 230 INV

  • Page 1 027908 4 2 3 8 8 7 CONTROL PANEL CUADRO DE MANDOS ORIGINALE N26683 Caution! Read “Warnings” inside carefully! Atención¡ Leer atentamente las “Advertencias” en el interior!
  • Page 2 AUX 3 = 5 Alimentación AUX 3 = 6 AUX 3 = 7 AUX 3 = 8 26 27 50 51 **With reverse logic, opening direction = 000 (DIR=right) **Con lógica inversión dirección de apertura = 000 (DIR=DER) SIRIO CBA 230 INV...
  • Page 3: Table Of Contents

    Steadily lit red light autoset ..MIN 1 - MAX 3 AUTO OPEN AUTO CLOSE Scroll up Scroll down re otes hidden button release desidered button O 01 Con rm/Switch on display Exit Menù SIRIO CBA 230 INV...
  • Page 4: Expi1

    MIN 1 - MAX 3 ..AUTO OPEN AUTO CLOSE Desplazar hacia arriba Desplazar hacia abajo RADIO suelte O 01 anad start tecla deseada Con rmación/ Encendido pantalla Retorno al menú principal fine SIRIO CBA 230 INV...
  • Page 5: Safe

    1 PHOT / 1 PHOT OP / 1 PHOT CL 1 BAR Bar 1 Bar 1 2 PHOT / 2 PHOT OP / 2 PHOT CL 2 BAR Bar 1 Bar 1 Bar 2 Bar 2 SIRIO CBA 230 INV...
  • Page 6: Sirio Cba 230 Inv

    62 63 64 65 70 71 72 73 74 75 76 77 78 50 51 52 70 71 72 73 74 75 76 77 78 STOP START SAFE 1 = 1 SAFE 2 = 7 SAFE 2 = 7 SAFE 3 = 1 SIRIO CBA 230 INV...
  • Page 7 - When switching logic con guration from right to left opening, do not swap over original connection of terminals 42-43. - En el paso de con guración lógica de apertura derecha/izquierda no invertir la conexión original de los bornes 42-43. SIRIO CBA 230 INV...
  • Page 8 Inverter alarm Check the inverter’s display for any error messages ErF1 / F2 limit switch error check limit switch connections *X= 0, 1, .., 9, A, B, C, D, E, F   0--- 10-- 150- 1520 password SIRIO CBA 230 INV...
  • Page 9: Auto Close

    - Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accord- SIRIO CBA 230 INV...
  • Page 10 All connecting cables must be kept far enough away from the dissipater. 220-230V 50-60Hz(*) Power supply 6) DO NOT EDIT INVERTER SETTINGS. PROGRAMMING TO BE CARRIED OUT VIA SIRIO CBA 230 INV CARD ONLy Low voltage/mains insulation > 2MOhm 500V -10 / +50°C...
  • Page 11 SAFE logic= 8 - Input configured as Bar 8k2 (fig.D, ref.5). Input for resistive edge 8K2. The command reverses movement for 2 sec.. (*) If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months. SIRIO CBA 230 INV...
  • Page 12: Automatic Closing Time [S]

    (**). (*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method. (**) Impact forces can be reduced by using deformable edges. 12 - SIRIO CBA 230 INV...
  • Page 13: Opening Speed [%]

    STOP + TCA STOP + TCA OPENING AFTER STOP OPENS OPENS OPENS The flashing light comes on at the same time as the motor(s) start. PRE-ALARM Pre-alarm   The flashing light comes on approx. 3 seconds before the motor(s) start. SIRIO CBA 230 INV...
  • Page 14 Output configured as Flashing light Receiver is configured for operation in rolling-code mode. Fixed-Code Clones are not accepted. FIXED CODE Fixed code   Receiver is configured for operation in fixed-code mode. Fixed-Code Clones are accepted. 14 - SIRIO CBA 230 INV...
  • Page 15 MASTER opposite leaves in local network: the control unit is the master in an opposite leaves net- work with no smart module (fig.F) Identifies board address from 0 to 127 in a local BFT network connection. [ ___ ] ADDRESS Address  ...
  • Page 16 ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed. OFF= W LINK programming disabled. 16 - SIRIO CBA 230 INV...
  • Page 17 ErF1 / F2 error final de carrera comprobar conexiones de los finales de carrera *X= 0, 1, .., 9, A, B, C, D, E, F   0--- 10-- 150- 1520 password SIRIO CBA 230 INV...
  • Page 18 - Eliminar los materiales de embalaje (plástico, cartón, poliestireno, etc.) según lo comercialización del producto, sin comprometerse a actualizar la presente previsto por las normas vigentes. No dejar sobres de nylon y poliestireno al alcance publicación. de los niños. 18 - SIRIO CBA 230 INV...
  • Page 19 6) NO MODIFICAR LAS CONFIGURACIONES DEL INVERTER: PARA LA Alimentación 220-230V 50-60Hz(*) PROGRAMACIÓN, INTERVENIR EXCLUSIVAMENTE EN LA TARjETA Aislamiento red/baja tensión > 2MOhm 500V SIRIO CBA 230 INV Temperatura de funcionamiento -10 / +50°C Protección térmica Inverter Resistencia dieléctrica rete/bt 3750V~ por 1 minuto Detección de obstáculos con encoder Presente...
  • Page 20 El mando invierte el movimiento durante 2 seg. (*) Si se instalan dispositivos de tipo “D” (tal como los define la EN12453), conectados en modo no comprobado, establecer un mantenimiento obligatorio con frecuencia al menos semestral. 20 - SIRIO CBA 230 INV...
  • Page 21 (**). (*) En la Unión Europea aplicar la EN12453 para los límites de fuerza, y la EN12445 para el método de medición. (**) Las fuerzas de impacto pueden ser reducidas utilizando cantos deformables. SIRIO CBA 230 INV...
  • Page 22 DESPUÉS ABRE ABRE ABRE DE STOP El indicador parpadeante se enciende simultáneamente cuando arranca/n el/los motor/es. PREALARMA Prealarma   El indicador parpadeante se enciende aproximadamente 3 segundos antes de que el/los motor/es arranque/n. 22 - SIRIO CBA 230 INV...
  • Page 23 Salida configurada como mando Luz de Cortesía. Configuración de Salida configurada como mando Luz Zona. AUX 3 la salida AUX 3. 26-27 Salida configurada como Luz escaleras Salida configurada como Alarma Salida configurada como Indicador parpadeante SIRIO CBA 230 INV...
  • Page 24 MASTER hojas contrapuestas en red local: la tarjeta es el master en una red de hojas contrapuestas sin de red BFT.) módulo inteligente. (fig.F) Identifica la dirección de 0 a 127 de la tarjeta en una conexión de red BFT local. [ ___ ] INDIRIZZO Dirección...
  • Page 25 ON = Habilita la programación a distancia de las entradas mediante un transmisor W LINK anteriormente memorizado. Esta habilitación permanece activa 3 minutos desde la última pulsación del radiomando W LINK. OFF= Programación W LINK deshabilitada. SIRIO CBA 230 INV...
  • Page 26 26 - SIRIO CBA 230 INV...
  • Page 27 SIRIO CBA 230 INV...
  • Page 28 CZECH REPUBLIC BFT USA BFT CZ S.R.O. 69800 Saint Priest Boca Raton POLAND www.bft-france.com Praha www.bft-usa.com BFT POLSKA SP. Z O.O. www.bft.it GERMANY 05-091 ZąBKI CHINA BFT TORANTRIEBSSYSTEME Gmb H www.bft.pl TURKEY BFT CHINA BFT OTOMATIK KAPI SISTEMELERI 90522 Oberasbach...