AIR CONDITIONER
Required tools for Installation Works
CAUTION
1 Phillips screw driver
2 Level gauge
R32
3 Electric drill, hole core drill (ø70 mm)
4 Hexagonal wrench (4 mm)
5 Spanner
REFRIGERANT
6 Pipe cutter
7 Reamer
This Air Conditioner contains and
8 Knife
operates with refrigerant R32.
9 Gas leak detector
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
10 Measuring tape
BY QUALIFIED PERSONNEL.
11 Thermometer
Refer to National, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance and/or service of this product.
SAFETY PRECAUTIONS
Read the following "SAFETY PRECAUTIONS" carefully before installation.
Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be installed.
The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below.
Incorrect installation due to ignoring of the instruction will cause harm or damage, and the seriousness is classifi ed by the following indications.
WARNING
This indication shows the possibility of causing death or serious injury.
CAUTION
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classifi ed by the symbols:
Symbol with white background denotes item that is PROHIBITED.
Symbol with dark background denotes item that must be carried out.
Carry out test running to confi rm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance as stated in
instructions. Please remind the customer to keep the operating instructions for future reference.
This appliance is not intended for accessibility by the general public.
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. Any unfi t method or using incompatible
material may cause product damage, burst and serious injury.
Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit on veranda of a high rise building, child may climb up to outdoor unit and
cross over the handrail causing an accident.
Do not use unspecifi ed cord, modifi ed cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances. Poor
contact, poor insulation or over current will cause electrical shock or fi re.
The appliance shall be stored in a well ventilated room with indoor fl oor area larger than A
(m²) [refer Table A] and without any continuously operating ignition
min
source. Keep away from open fl ames, any operating gas appliances or any operating electric heater. Else, it may explode and cause injury or death.
Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen.
Do not insert your fi ngers or other objects into the unit, high speed rotating fan may cause injury.
Do not sit or step on the unit, you may fall down accidentally.
The appliance shall be installed, and/or operated in a room with fl oor area larger than A
(m²) [refer Table A] and keep away from ignition sources, such as heat/
min
sparks/open fl ame or hazardous areas such as gas appliances, gas cooking, reticulated gas supply systems or electric cooking appliances, etc.
Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing.
When installing or relocating air conditioner, do not let any substance other than the specifi ed refrigerant, eg. air etc mix into refrigeration cycle (piping).
Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.
Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, fl ame, sparks, or other sources of ignition.
Else, it may explode and cause injury or death.
Do not add or replace refrigerant other than specifi ed type. It may cause product damage, burst and injury etc.
Do not perform fl are connection inside a building or dwelling or room, when joining the heat exchanger of indoor unit with interconnecting piping. Refrigerant
connection inside a building or dwelling or room must be made by brazing or welding. Joint connection of indoor unit by fl aring method can only be made at outdoor or
at outside of a buidling or dwelling or room. Flare connection may cause gas leak and fl ammable atmosfere.
For R32 model, use piping, fl are nut and tools which is specifi ed for R32 refrigerant. Using of existing (R22) piping, fl are nut and tools may cause abnormally high
pressure in the refrigerant cycle (piping), and possibly result in explosion and injury.
Thickness for copper pipes used with R32 must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm.
It is desirable that the amount of residual oil less than 40 mg/10 m.
Engage authorized dealer or specialist for installation. If installation done by the user is incorrect, it will cause water leakage, electrical shock or fi re.
For refrigeration system work, install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fi re.
Use the attached accessories parts and specifi ed parts for installation. Otherwise, it will cause the set to fall, water leakage, fi re or electrical shock.
Install at a strong and fi rm location which is able to withstand weight of the set. If the strength is not enough or installation is not properly done, the set will drop and
cause injury.
For electrical work, follow the national regulation, legislation and this installation instructions. An independent circuit and single outlet must be used. If electrical circuit
capacity is not enough or defect found in the electrical work, it will cause electrical shock or fi re.
Do not use joint cable for indoor / outdoor connection cable. Use the specifi ed indoor/outdoor connection cable, refer to instruction 5 CONNECT THE CABLE TO
THE INDOOR UNIT and connect tightly for indoor/outdoor connection. Clamp the cable so that no external force will have impact on the terminal. If connection or
fi xing is not perfect, it will cause heat up or fi re at the connection.
Wire routing must be properly arranged so that control board cover is fi xed properly. If control board cover is not fi xed perfectly, it will cause fi re or electrical shock.
This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD), with sensitivity of 30mA at
0.1 sec or less. Otherwise, it may cause electrical shock and fi re in case of equipment breakdown or insulation breakdown.
During installation, install the refrigerant piping properly before running the compressor. Operation of compressor without fi xing refrigeration piping and valves at
opened position will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.
During pump down operation, stop the compressor before removing the refrigeration piping. Removal of refrigeration piping while compressor is operating and valves
are opened will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.
Tighten the fl are nut with torque wrench according to specifi ed method. If the fl are nut is over-tightened, after a long period, the fl are may break and cause refrigerant
gas leakage.
After completion of installation, confi rm there is no leakage of refrigerant gas. It may generate toxic gas when the refrigerant contacts with fi re.
Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with fi re.
Be aware that refrigerants may not contain an odour.
This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and telephone.
Otherwise, it may cause electrical shock in case of equipment breakdown or insulation breakdown.
CAUTION
Do not install the unit in a place where leakage of fl ammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fi re.
Prevent liquid or vapor from entering sumps or sewers since vapor is heavier than air and may form suffocating atmospheres.
Do not release refrigerant during piping work for installation, re-installation and during repairing refrigeration parts. Take care of the liquid refrigerant, it may cause
frostbite.
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
Do not touch the sharp aluminium fi n, sharp parts may cause injury.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture.
Select an installation location which is easy for maintenance.
Incorrect installation, service or repair of this air conditioner may increase the risk of rupture and this may result in loss damage or injury and/or property.
Power supply connection to the room air conditioner.
Use power supply cord 3 x 1.5 mm² (3/4 ~ 1.75HP), 3 x 2.5 mm² (2.0HP) type designation 60245 IEC 57 or heavier cord.
Connect the power supply cord of the air conditioner to the mains using one of the following method.
Power supply point should be in easily accessible place for power disconnection in case of emergency.
In some countries, permanent connection of this air conditioner to the power supply is prohibited.
1) Power supply connection to the receptacle using power plug.
Use an approved 15/16A (3/4 ~ 1.75HP), 16A (2.0HP) power plug with earth pin for the connection to the socket.
2) Power supply connection to a circuit breaker for the permanent connection.
Use an approved 16A (3/4 ~ 2.0HP) circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap.
Installation work.
It may need two people to carry out the installation work.
PRECAUTION FOR USING R32 REFRIGERANT
The basic installation work procedures are the same as conventional refrigerant (R410A, R22) models.
However, pay careful attention to the following points:
Since the working pressure is higher than that of refrigerant R22 models, some of the piping and installation and service tools are special.
12 Megameter
(See "2.1. Special tools for R32 (R410A)".)
13 Multimeter
Especially, when replacing a refrigerant R22 model with a new refrigerant R32 model, always replace the conventional piping and fl are nuts with the R32 and R410A
14 Torque wrench
piping and fl are nuts on the outdoor unit side.
18 N•m (1.8 kgf•m)
For R32 and R410A, the same fl are nut on the outdoor unit side and pipe can be used.
42 N•m (4.3 kgf•m)
55 N•m (5.6 kgf•m)
Models that use refrigerant R32 and R410A have a different charging port thread diameter to prevent erroneous charging with refrigerant R22 and for safety.
65 N•m (6.6 kgf•m)
Therefore, check beforehand. [The charging port thread diameter for R32 and R410A is 12.7 mm (1/2 inch).]
100 N•m (10.2 kgf•m)
Be more careful than R22 so that foreign matter (oil, water, etc.) does not enter the piping.
15 Vacuum pump
Also, when storing the piping, securely seal the opening by pinching, taping, etc. (Handling of R32 is similar to R410A.)
16 Gauge manifold
Installation (Space)
1.
Must ensure the installation of pipe-work shall be kept to a minimum. Avoid use dented pipe and do not allow acute bending.
Must ensure that pipe-work shall be protected from physical damage.
Must comply with national gas regulations, state municipal rules and legislation. Notify relevant authorities in accordance with all applicable regulations.
Must ensure mechanical connections be accessible for maintenance purposes.
In cases that require mechanical ventilation, ventilation openings shall be kept clear of obstruction.
When disposal of the product, do follow to the precautions in #12 and comply with national regulations.
Always contact to local municipal offi ces for proper handling.
Interconnecting refrigerant pipework, i.e. pipework external to the unitary components, should be marked with a Class label (see Figure 9.1 of Code of Practice)
every two metres where the pipework is visible. This includes pipework located in a ceiling space or any void which a person may access for maintenance or repair
work within that space.
2.
Servicing
2-1. Service personnel
Any qualifi ed person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certifi cate from an industry-accredited
assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specifi cation.
Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel
shall be carried out under the supervision of the person competent in the use of fl ammable refrigerants.
Servicing shall be performed only as recommended by the manufacturer.
2-2. Work
Prior to beginning work on systems containing fl ammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised.
For repair to the refrigerating system, the precautions in #2-2 to #2-8 must be followed before conducting work on the system.
Work shall be undertaken under a controlled procedure so as to minimize the risk of a fl ammable gas or vapour being present while the work is being performed.
All maintenance staff and others working in the local area shall be instructed and supervised on the nature of work being carried out.
Avoid working in confi ned spaces.
Wear appropriate protective equipment, including respiratory protection, as conditions warrant.
Ensure that the conditions within the area have been made safe by limit of use of any fl ammable material. Keep all sources of ignition and hot metal surfaces
away.
2-3. Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially fl ammable
atmospheres.
Ensure that the leak detection equipment being used is suitable for use with fl ammable refrigerants, i.e. non sparking, adequately sealed or intrinsically safe.
In case of leakage/spillage happened, immediately ventilate area and stay upwind and away from spill/release.
In case of leakage/spillage happened, do notify persons down wind of the leaking/spill, isolate immediate hazard area and keep unauthorized personnel out.
2-4. Presence of fi re extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fi re extinguishing equipment shall be available at hand.
Have a dry powder or CO
fi re extinguisher adjacent to the charging area.
2
2-5. No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained fl ammable refrigerant shall
use any sources of ignition in such a manner that it may lead to the risk of fi re or explosion. He/She must not be smoking when carrying out such work.
All possible ignition sources, including cigarette smoking, should be kept suffi ciently far away from the site of installation, repairing, removing and disposal, during
which fl ammable refrigerant can possibly be released to the surrounding space.
Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no fl ammable hazards or ignition risks.
"No Smoking" signs shall be displayed.
2-6. Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work.
A degree of ventilation shall continue during the period that the work is carried out.
The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
2-7. Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fi t for the purpose and to the correct specifi cation.
At all times the manufacturer's maintenance and service guidelines shall be followed.
If in doubt consult the manufacturer's technical department for assistance.
The following checks shall be applied to installations using fl ammable refrigerants.
- The charge size is in accordance with the room size within which the refrigerant containing parts are installed.
- The ventilation machinery and outlets are operating adequately and are not obstructed.
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
- Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected.
- Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing
components, unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded.
2-8. Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures.
Initial safety checks shall include but not limit to:-
- That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking.
- That there is no live electrical components and wiring are exposed while charging, recovering or purging the system.
- That there is continuity of earth bonding.
At all times the manufacturer's maintenance and service guidelines shall be followed.
If in doubt consult the manufacturer's technical department for assistance.
If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used.
The owner of the equipment must be informed or reported so all parties are advised thereinafter.
Repairs to sealed components
3.
During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers,
etc.
If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the
most critical point to warn of a potentially hazardous situation.
Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of
protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specifi cation, damage to seals,
incorrect fi tting of glands, etc.
Ensure that apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of fl ammable atmospheres.
Replacement parts shall be in accordance with the manufacturer's specifi cations.
NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment.
Intrinsically safe components do not have to be isolated prior to working on them.
4.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for
the equipment in use.
Intrinsically safe components are the only types that can be worked on while live in the presence of a fl ammable atmosphere.
The test apparatus shall be at the correct rating.
Replace components only with parts specifi ed by the manufacturer. Unspecifi ed parts by manufacturer may result ignition of refrigerant in the atmosphere from a
leak.
5.
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects.
The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
6.
Detection of fl ammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching or detection of refrigerant leaks.
A halide torch (or any other detector using a naked fl ame) shall not be used.
7.
Leak detection methods
Electronic leak detectors shall be used to detect fl ammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration.
(Detection equipment shall be calibrated in a refrigerant-free area.)
Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate
percentage of gas (25 % maximum) is confi rmed.
Leak detection fl uids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the
refrigerant and corrode the copper pipe-work.
If a leak is suspected, all naked fl ames shall be removed/extinguished.
If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a
part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
8.
Removal and evacuation
When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used.
However, it is important that best practice is followed since fl ammability is a consideration.
The following procedure shall be adhered to:
• remove refrigerant -> • purge the circuit with inert gas -> • evacuate -> • purge again with inert gas -> • open the circuit by cutting or brazing
The refrigerant charge shall be recovered into the correct recovery cylinders.
The system shall be "fl ushed" with OFN to render the unit safe.
This process may need to be repeated several times.
Compressed air or oxygen shall not be used for this task.
Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fi ll until the working pressure is achieved, then venting to atmosphere, and fi nally pulling down to a vacuum.
This process shall be repeated until no refrigerant is within the system.
When the fi nal OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place.
WARNING
This operation is absolutely vital if brazing operations on the pipe work are to take place.
Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
9.
Charging procedures
In addition to conventional charging procedures, the following requirements shall be followed.
- Ensure that contamination of different refrigerants does not occur when using charging equipment.
- Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
- Label the system when charging is complete (if not already).
- Extreme care shall be taken not to over fi ll the refrigeration system.
Prior to recharging the system it shall be pressure tested with OFN (refer to #7).
The system shall be leak tested on completion of charging but prior to commissioning.
CAUTION
A follow up leak test shall be carried out prior to leaving the site.
Electrostatic charge may accumulate and create a hazardous condition when charging and discharging the refrigerant.
To avoid fi re or explosion, dissipate static electricity during transfer by grounding and bonding containers and equipment before charging/discharging.
10.
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its details.
It is recommended good practice that all refrigerants are recovered safely.
Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant.
It is essential that electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure ensure that:
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various
parts of the system.
Electrostatic charge may accumulate and create a hazardous condition when charging or discharging the refrigerant.
To avoid fi re or explosion, dissipate static electricity during transfer by grounding and bonding containers and equipment before charging/discharging.
11.
Labelling
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant.
The label shall be dated and signed.
Ensure that there are labels on the equipment stating the equipment contains fl ammable refrigerant.
12.
Recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed.
Ensure that the correct number of cylinders for holding the total system charge are available.
All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant).
Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order.
Recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of fl ammable refrigerants.
In addition, a set of calibrated weighing scales shall be available and in good working order.
Hoses shall be complete with leak-free disconnect couplings and in good condition.
Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a
refrigerant release.
Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged.
Do not mix refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that fl ammable refrigerant does not remain within the lubricant.
The evacuation process shall be carried out prior to returning the compressor to the suppliers.
Only electric heating to the compressor body shall be employed to accelerate this process.
When oil is drained from a system, it shall be carried out safely.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
CAUTION
CAUTION
CAUTION
Attached accessories
No.
Accessories part
Installation plate
1
3
Installation plate fi xing
screw
2
Remote Control
3
Applicable piping kit
CZ-3F5, 7BP
CZ-4F5, 7, 10BP
CZ-52F5, 7, 10BP
  Do not install the unit in excessive oil fume area such as kitchen, workshop and etc.
  There should not be any heat source or steam near the unit.
  There should not be any obstacles blocking the air circulation.
  A place where air circulation in the room is good.
  A place where drainage can be easily done.
  A place where noise prevention is taken into consideration.
  Do not install the unit near the door way.
  Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
  Installation height for indoor unit must be at least 2.5 m.
  If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat
radiation from the condenser is not obstructed.
  There should not be any animal or plant which could be affected by hot air discharged.
  Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
  Do not place any obstacles which may cause a short circuit of the discharged air.
  If piping length is over the [piping length for additional gas], additional refrigerant should be
added as shown in the table.
Table A
Model
Z7***, XZ7***
Z9***, XZ9***
Z12***, XZ12***
Z15***
Z18***, XZ18***
Example: For Z9***
If the unit is installed at 10 m distance, the quantity of additional refrigerant should be
25 g .... (10-7.5) m x 10 g/m = 25 g.
A
= (M / (2.5 x (LFL)
min
A
= Required minimum room area, in m²
min
M
= Refrigerant charge amount in appliance, in kg
LFL = Lower fl ammable limit (0.306 kg/m³)
h
= Installation height of the appliance (1.8 m for wall mounted)
0
f) Make sure that cylinder is situated on the scales before recovery takes place.
g) Start the recovery machine and operate in accordance with manufacturer's instructions.
h) Do not over fi ll cylinders. (No more than 80 % volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
mechanical handling equipment is available, if required, for handling refrigerant
j) When the cylinders have been fi lled correctly and the process completed, make sure that the cylinders
cylinders;
and the equipment are removed from site promptly and all isolation valves on the equipment are closed
all personal protective equipment is available and being used correctly;
off.
the recovery process is supervised at all times by a competent person;
k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned
recovery equipment and cylinders conform to the appropriate standards.
and checked.
Indoor/Outdoor Unit Installation Diagram
This symbol shows that this equipment uses a fl ammable refrigerant. If the
Piping direction
refrigerant is leaked, together with an external ignition source, there is a
possibility of ignition.
Right
This symbol shows that the Operation Manual should be read carefully.
Right
Rear
This symbol shows that a service personnel should be handling this
Left
Right
equipment with reference to the Installation Manual.
Rear
bottom
This symbol shows that there is information included in the Operation
Manual and/or Installation Manual.
Qty. No.
Accessories part
Qty. No.
Accessories part
Qty.
Battery
Drain elbow
4
1
4
2
7
1
Remote control holder
5
1
5
Remote control holder
fi xing screw
1
6
2
50 mm
or more
Piping size
Gas
Liquid
9.52 mm (3/8")
6.35 mm (1/4")
12.7 mm (1/2")
6.35 mm (1/4")
15.88 mm (5/8")
6.35 mm (1/4")
SELECT THE BEST LOCATION
Insulation of piping connections
INDOOR UNIT
Carry out insulation after
checking for gas leaks and
secure with vinyl tape.
Attaching the remote control holder to the wall
Remote control holder fi xing screws 6
OUTDOOR UNIT
Remote
control 3
Floor
Piping
Piping size
Min.
Max.
Indoor
Capacity
Std.
Max.
Additional
Length
Piping
Piping
Length
Elevation
Refrigerant
for add.
A
W
Length
Length
min
(m)
(m)
(g/m)
gas
(HP)
Gas
Liquid
(m²)
It is advisable to
(m)
(m)
(m)
avoid more than 2
blockage directions.
3/4HP
15
3
15
10
7.5
0.66
9.52mm
For better ventilation
1.0HP
15
3
15
10
7.5
0.82
(3/8")
& multiple-outdoor
6.35mm
1.5HP
5
15
3
15
10
7.5
0.93
installation, please
(1/4")
consult authorized
1.75HP 12.7mm
15
3
15
10
7.5
0.85
dealer/specialist.
(1/2")
2.0HP
15
3
20
15
7.5
1.41
This illustration is for
explanation purposes only.
The indoor unit will actually
face a different way.
(5/4)
x h
)) ²
0
Attention not to bend
WARNING
up drain hose
(Front side)
Flare connection only
at outside of building
Left
Left bottom
Installation parts you
should purchase ( )
Installation plate 1
Bushing-Sleeve ( )
Sleeve ( )
Putty ( )
(Gum Type Sealer)
Bend the pipe as
closely on the wall
(Left and right are identical)
as possible, but
be careful that it
doesn't break.
Power supply cord
( )
Vinyl tape
Remote control holder 5
Saddle ( )
Connection cable
Liquid side piping
( )
Gas side piping ( )
Additional drain hose
( )
ENGLISH
ACXF60-01930-AB
1/2
PRINTED IN MALAYSIA

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic Z7 SERIES

  • Page 1 PRECAUTION FOR USING R32 REFRIGERANT • This process may need to be repeated several times. AIR CONDITIONER • Compressed air or oxygen shall not be used for this task. • The basic installation work procedures are the same as conventional refrigerant (R410A, R22) models. •...
  • Page 2: Indoor Unit Installation

    INDOOR UNIT OUTDOOR UNIT SELECT THE BEST LOCATION SELECT THE BEST LOCATION INDOOR UNIT INSTALLATION CONNECT THE PIPING (Refer to “Select the best location” section) (Refer to “Select the best location” section) • Connecting The Piping to Indoor Do not turn over the unit without it’s shock absorber during pull out the piping. It may cause intake grille damage.
  • Page 3: Aire Acondicionado

    PRECAUCIONES PARA EL USO DEL REFRIGERANTE R32 • Es posible que sea necesario repetir este proceso varias veces. AIRE ACONDICIONADO • Para esta tarea no debe utilizarse aire comprimido ni oxígeno. • Los procedimientos básicos de trabajo de instalación son los mismos que los de los modelos con refrigerantes convencionales (R410A, R22). •...
  • Page 4: Unidad Interior

    UNIDAD INTERIOR UNIDAD EXTERIOR SELECCIONE LA MEJOR UBICACIÓN SELECCIONE LA MEJOR UBICACIÓN INSTALACIÓN DE UNIDAD INTERIOR CONECTAR LA TUBERÍA (Vea la sección “Seleccione la mejor ubicación”) (Vea la sección “Seleccione la mejor ubicación”) • Conectar la Tubería la Interior No dé la vuelta a la unidad sin su amortiguador de golpes cuando retire la tubería. Podría causar daños a la rejilla de entrada.
  • Page 5: Misure Di Sicurezza

    PRECAUZIONI PER L’USO DEL REFRIGERANTE R32 • Potrebbe essere necessario ripetere più volte questa procedura. CLIMATIZZATORE • Non utilizzare aria compressa o ossigeno per questa operazione. • Le procedure di installazione di base sono le stesse dei modelli di refrigerante convenzionali (R410A, R22). •...
  • Page 6: Unità Interna

    UNITÀ INTERNA UNITÀ ESTERNA SCEGLIERE LA POSIZIONE MIGLIORE SCEGLIERE LA POSIZIONE MIGLIORE INSTALLAZIONE DEL UNITÀ INTERNA COLLEGARE I TUBI (Vedi il paragrafo “Scegliere la posizione migliore”) (Vedi il paragrafo “Scegliere la posizione migliore”) • Collegamento delle tubazioni all’interno Durante l’estrazione della tubazione non capovolgere l’unità senza l’ammortizzatore. Altrimenti potrebbero esserci danni alla griglia di aspirazione.
  • Page 7: Air Conditioner

    VOORZORGSMAATREGELEN VOOR GEBRUIK VAN R32-KOELMIDDEL • Het kan zijn dat dit proces een paar keer moet worden herhaald. AIRCONDITIONER • Voor deze taak mag geen perslucht of zuurstof worden gebruikt. • De procedures voor de standaard installatiewerkzaamheden zijn hetzelfde als voor modellen met een conventioneel koelmiddel (R410A, R22). •...
  • Page 8 BINNENUNIT BUITENUNIT BEPAAL DE BESTE PLAATS BEPAAL DE BESTE PLAATS INSTALLATIE VAN DE BINNENUNIT SLUIT DE LEIDING AAN (Zie deel "Bepaal de beste plaats") (Zie deel "Bepaal de beste plaats") • Het buissysteem aan het binnenapparaat aansluiten Kantel, bij het uittrekken van de leiding, het apparaat niet zonder zijn schokbreker; de inlaatrooster zou beschadigd kunnen worden. •...
  • Page 9: Precauções De Segurança

    • PRECAUÇÃO ACERCA DO USO DO REFRIGERANTE R32 Este processo pode precisar de ser repetido várias vezes. APARELHO DE AR • Não utilize ar comprimido ou oxigénio para esta tarefa. • • A lavagem será alcançada quebrando o vácuo no sistema com OFN e continuando a encher até a pressão de trabalho ser alcançado, e ventilando para a atmosfera e, por último, baixando até uma situação de vácuo. Os procedimentos de trabalho da instalação básica são iguais aos dos modelos com refrigerante (R410A, R22) convencionais.
  • Page 10: Instalação Da Unidade Interior

    UNIDADE INTERIOR UNIDADE EXTERIOR ESCOLHA O MELHOR LOCAL ESCOLHA O MELHOR LOCAL INSTALAÇÃO DA UNIDADE INTERIOR LIGUE A TUBAGEM (Consulte a secção “Escolha o melhor local”) (Consulte a secção “Escolha o melhor local”) • Ligação do Tubo ao Interior Não vire a unidade sem o seu amortecedor durante a remoção da tubagem. Poderá...
  • Page 11 ΠΡΟΦΥΛΑΞΕΙΣ ΓΙΑ ΤΗ ΧΡΗΣΗ ΤΟΥ ΨΥΚΤΙΚΟΥ ΜΕΣΟΥ R32 • Αυτή η διαδικασία μπορεί να χρειαστεί να επαναληφθεί αρκετές φορές. • Δεν θα χρησιμοποιηθεί συμπιεσμένος αέρας ή οξυγόνο για αυτήν την εργασία. ΚΛΙΜΑΤΙΣΤΙΚΟ • Οι βασικές διαδικασίες εργασιών εγκατάστασης είναι οι ίδιες όπως και για τα μοντέλα συμβατικών ψυκτικών μέσων (R410A, R22). •...
  • Page 12: Εσωτερικη Μοναδα

    ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ ΕΞΩΤΕΡΙΚΗ ΜΟΝΑΔΑ ΕΠΙΛΟΓΗ ΤΗΣ ΚΑΛΥΤΕΡΗΣ ΘΕΣΗΣ ΤΟΠΟΘΕΤΗΣΗΣ ΕΠΙΛΟΓΗ ΤΗΣ ΚΑΛΥΤΕΡΗΣ ΘΕΣΗΣ ΤΟΠΟΘΕΤΗΣΗΣ ΕΓΚΑΤΑΣΤΑΣΗ ΕΣΩΤΕΡΙΚΗΣ ΜΟΝΑΔΑΣ ΣΥΝΔΕΣΗ ΤΗΣ ΣΩΛΗΝΩΣΗΣ (Ανατρέξτε στην παράγραφο "Επιλογή της καλύτερης θέσης τοποθέτησης") (Ανατρέξτε στην παράγραφο "Επιλογή της καλύτερης θέσης τοποθέτησης") • Σύνδεση του Σωλήνα με την Εσωτερική μονάδα Μην...
  • Page 13: Предпазни Мерки

    МЕРКИ ЗА БЕЗОПАСНОСТ ПРИ ИЗПОЛЗВАНЕ ХЛАДИЛЕН АГЕНТ R32 • Този процес може да се наложи да се повтори няколко пъти. • Не трябва да се използва компресиран въздух или кислород за тази задача. КЛИМАТИК • Основните процедури за монтаж са същите, както при моделите със стандартен хладилен агент (R410A, R22). •...
  • Page 14: Вътрешна Част

    ВЪТРЕШНА ЧАСТ ВЪНШНА ЧАСТ ИЗБЕРЕТЕ НАЙ-ПОДХОДЯЩОТО МЯСТО ИЗБЕРЕТЕ НАЙ-ПОДХОДЯЩОТО МЯСТО МОНТАЖ НА ВЪТРЕШНИЯ УРЕД СВЪРЗВАНЕ НА ТРЪБИТЕ (Виж раздел “Изберете най-подходящото място”) (Виж раздел “Изберете най-подходящото място”) • Свързване на тръбата към вътрешния агрегат Не обръщайте уреда без страничната му опаковка при изтегляне на тръбите. Може...
  • Page 15: Consignes De Sécurité

    PRÉCAUTIONS POUR L’UTILISATION DU RÉFRIGÉRANT R32 • Il peut s’avérer nécessaire de répéter ce processus plusieurs fois. • L’air ou l’oxygène comprimé ne doivent pas être utilisés pour cette tâche. CLIMATISEUR • • La chasse doit se faire en rompant le vide dans le système avec de l’azote sans oxygène (OFN) et en continuant à remplir jusqu’à obtention de la pression de fonctionnement, puis en purgeant dans l’atmosphère et enfi n en tirant Les procédures d’installation de base sont les mêmes que pour les modèles à...
  • Page 16: Unité Intérieure

    UNITÉ INTÉRIEURE UNITÉ EXTÉRIEURE CHOIX DE L’EMPLACEMENT CHOIX DE L’EMPLACEMENT INSTALLATION DE L’UNITÉ INTÉRIEURE RACCORDER LA TUYAUTERIE (Cf. chapitre « Choix de l’emplacement ») (Cf. chapitre « Choix de l’emplacement ») • Ne faites pas pivoter l’unité sans son amortisseur pendant le tirage des tuyauteries. Raccordement du tube vers l’intérieur La grille d’admission pourrait être endommagée.
  • Page 17 • Dieser Prozess muss möglicherweise mehrmals wiederholt werden. VORSICHTSMASSNAHMEN FÜR DIE VERWENDUNG DES KÄLTEMITTELS VOM TYP R32 • Druckluft oder Sauerstoff dürfen für diese Aufgabe nicht verwendet werden. • Eine Leerung soll erreicht werden, indem das Vakuum im System mit sauerstofffreiem Stickstoff unterbrochen und weiter gefüllt wird, bis der Betriebsdruck erreicht ist. Dann soll in die Atmosphäre entlüftet und schließlich wieder KLIMAGERÄT ein Vakuum hergestellt werden.
  • Page 18 INNENGERÄT AUßENGERÄT WAHL DES STANDORTS WAHL DES STANDORTS MONTAGE DES INNENGERÄTS ANSCHLIESSEN DER ROHRLEITUNG (Siehe Abschnitt „Wahl des Standorts“) (Siehe Abschnitt „Wahl des Standorts“) • Anschluss am Innengerät Legen Sie das Gerät nicht ohne seine Schutzpolster auf die Frontseite, um die Leitung herauszuziehen. ANBRINGEN DER MONTAGEPLATTE Sonst kann das Ansauggitter beschädigt werden.
  • Page 19 • Ovaj postupak će se možda morati ponoviti nekoliko puta. MJERE OPREZA ZA KORIŠTENJE RASHLADNOG SREDSTVA R32 KLIMATIZACIJSKI • Za ovaj zadatak neće se koristiti komprimirani zrak ili kisik. • • Ispiranje će se izvršiti odspajanjem vakuuma u sustavu s OFN i nastavlja se puniti sve dok se ne dostigne radni tlak, potom se vrši ispuštanje u atmosferu, i na kraju izvlačenje vakuuma. Osnovni postupci radova na instaliranju isti su kao i kod standardnih modela rashladnih sredstava (R410A, R22).
  • Page 20 UNUTARNJA JEDINICA VANJSKA JEDINICA ODABIR NAJBOLJE LOKACIJE ODABIR NAJBOLJE LOKACIJE MONTAŽA UNUTARNJE JEDINICE PRIKLJUČIVANJE CIJEVI (Pogledajte odlomak »Odabir najbolje lokacije«) (Pogledajte odlomak »Odabir najbolje lokacije«) Priključivanje voda na unutarnju jedinicu • Nemojte preokretati jedinicu bez njezinog amortizera tijekom izvlačenja voda. To može dovesti do oštećenja rešetke za dovod.
  • Page 21 Bu işlemin birkaç defa tekrar edilmesi gerekebilir. R32 SOĞUTUCUSU KULLANIMI, ÖNLEMLER • • Sıkıştırılmış hava ya da oksijen, bu görev için kullanılmamalıdır. KLİMA Boşaltma, OFN ile sistemdeki vakumu keserek ve çalışma basıncına ulaşıncaya kadar doldurmaya devam ederek, daha sonra atmosferde havalandırarak ve son olarak bir vakuma indirerek elde edilmelidir. Temel tesisat çalışma prosedürleri, klasik soğutucu modeli (R410A, R22) ile aynıdır.
  • Page 22 İÇ ÜNİTE DIŞ ÜNİTE EN İYİ KONUMUN SEÇİLMESİ EN İYİ KONUMUN SEÇİLMESİ İÇ MEKAN ÜNİTESİ KURULUMU BORU TESİSATININ BAĞLANMASI (“En iyi konumun seçilmesi” kesimine bakınız) (“En iyi konumun seçilmesi” kesimine bakınız) Boru Tesisatının İç Mekana Bağlanması • Boru tesisatının dışarı çekilmesi sırasında üniteyi şok emicisi olmadan döndürmeyin. Bu, hava giriş...

Table of Contents