SELECT THE BEST LOCATION
(Refer to "Select the best location" section)
2
HOW TO FIX INSTALLATION PLATE
The mounting wall shall be strong and solid enough to prevent it from vibration.
Wall
Wall
More than 1
More than 1
More than
2 screw
2
3
4
Installation plate 1
B
266 mm
PIPE
PIPE
Measuring
For best strength of
HOLE
HOLE
CENTER
CENTER
Tape

INDOOR unit installation,

A
C
128mm TO
128mm TO
PIPE HOLE
it is highly recommended
PIPE HOLE
CENTER
CENTER
128 mm
to locate " " at 5 position
as shown.
Dimension
Model
1
2
3
4
Z7***, XZ7***, Z9***, XZ9***
Z12***, XZ12***, Z15***
515 mm
82 mm
460 mm
460 mm
Z18***, XZ18***
The center of installation plate should be at more than 1 at right and left of the wall.
The distance from installation plate edge to ceiling should more than 2.
From installation plate center to unit's left side is 3.
From installation plate center to unit's right side is 4.
b
: For left side piping, piping connection for liquid should be about 5 from this line.
: For left side piping, piping connection for gas should be about 6 from this line.
1.
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge.
Drill the piping plate hole with ø70 mm hole-core drill.
2.
Line according to the left and right side of the installation plate.
The meeting point of the extended line is the center of the hole.
Another method is by putting measuring tape at position as shown in the diagram above.
The hole center is obtained by measuring the distance namely 128 mm for left and right hole respectively.
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side.
3
TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING
1.
Insert the piping sleeve to the hole.
Wall
2.
Fix the bushing to the sleeve.
Indoor
Outdoor
Cut the sleeve until it extrudes about 15 mm from the wall.
3.
15 mm
CAUTION
When the wall is hollow, please be sure to use
the sleeve for tube assembly to prevent dangers
Sleeve for tube
caused by mice biting the connection cable.
assembly
4.
Finish by sealing the sleeve with putty or caulking
compound at the fi nal stage.
ø70 mm through hole
5
CONNECT THE CABLE TO THE INDOOR UNIT
The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille.
1 Install the indoor unit on the installing holder that mounted on the wall.
2 Open the front panel and grille door by loosening the screw.
3 Cable connection to the power supply through Isolating Devices (Disconnecting means).
Connect the approved polychloroprene sheathed power supply cord 3 x 1.5 mm
2
(3/4 ~ 1.75HP) or 3 x 2.5 mm
60245 IEC 57 or heavier cord to the terminal board, and connect the other end of the cable to Isolating Devices (Disconnecting means).
Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or otherwise) is too short.
In unavoidable case, joining of power supply cord between isolating devices and terminal board of air conditioner shall be done by using
approved socket and plug rated 15/16A (3/4 ~ 1.75HP) or 16A (2.0HP). Wiring work to both socket and plug must follow to national wiring
standard.
4 Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement.
5 Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 x 1.5 mm
2.5 mm
2
(2.0HP) fl exible cord, type designation 60245 IEC 57 or heavier cord.
6 Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right escapement.
7 Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor unit according to the diagram below.
Terminals on the outdoor unit
S1 2
3
Colour of wires (connection cable)
Terminals on the indoor unit
L
1
N
S1 2
3
(Power supply cord)
Terminal Board
(L) (N)
Terminals on the isolating devices
(Disconnecting means)
8 Secure the power supply cord and connection cable onto
the control board with the holder.
9 Close grille door by tighten with screw and close the
Recommended
length (mm)
front panel.
a
b
c
d
e
f
g
Recommended
length (mm)
55 35 35 50 40 35 60
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0 mm
contact gap.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the
Tape
Holder
same to the indoor's respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other
AC wires as shown in the fi gure for the electrical safety in case of the
Power supply
Indoor & outdoor
slipping out of the cord from the anchorage.
cord
connection cable
WIRE STRIPPING, CONNECTING
Power supply cord
REQUIREMENT
Isolating Devices

Outdoor unit

Wire stripping
RISK OF FIRE
JOINING OF
WIRES MAY
CAUSE
No loose strand
WARNING
OVERHEATING
when inserted
AND FIRE.
Indoor/outdoor
connection
Do not joint wires
terminal board
5 mm or more
(gap between wires)
OR
Conductor
Conductor over
Conductor not
OR
fully inserted
inserted
fully inserted
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national
ACCEPT
PROHIBITED
PROHIBITED
wiring rules.
CUTTING AND FLARING THE PIPING
1.
Please cut using pipe cutter and then remove the burrs.
 Improper fl aring 
2.
Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused.
Turn the piping end down to avoid the metal powder entering the pipe.
3.
Please make fl are after inserting the fl are nut onto the copper pipes.
Pipe
Handle
Inclined Surface
0 – 0.5 mm
Reamer
Bar
Bar
damaged
Yoke
Core
When properly fl ared, the internal surface of the
fl are will evenly shine and be of even thickness.
Copper pipe
Point down
Red arrow mark
Clamp handle
Since the fl are part comes into contact with the
1. To cut
2. To remove burrs
3. To fl are
connections, carefully check the fl are fi nish.
INDOOR UNIT
4
INDOOR UNIT INSTALLATION
Do not turn over the unit without it's shock absorber during pull out the piping.
It may cause intake grille damage.
Use shock absorber during pull out the piping to protect the intake grille from damage.
Wall
Piping
Indoor unit
Intake grille
266 mm
1. FOR THE RIGHT REAR PIPING
Right Rear piping
Step-1
Pull out the Indoor piping
Tape it with piping in a
position as mentioned
128 mm
in Fig. below.
Step-2
Install the Indoor Unit
Step-3
Secure the Indoor Unit
5
6
Cover for
Drain
the right
hose
piping
43 mm
95 mm
Insert the power supply cord and
Step-4
connection cable
Insert the cables from bottom of the
How to keep the cover
unit through the control board hole until
In case of the cover is cut, keep
terminal board area.
the cover at the rear of chassis as
shown in the illustration for future
reinstallation.
2. FOR THE RIGHT AND RIGHT
(Left, right and 2 bottom covers for
BOTTOM PIPING
piping.)
Step-1
Pull out the Indoor piping
Right and Right Bottom piping
Step-2
Install the Indoor Unit
Tape it with piping in a
position as mentioned
in Fig. below.
Insert the power supply cord and
Step-3
connection cable
Insert the cables from bottom of the
unit through the control board hole until
terminal board area.
Drain hose
Step-4
Secure the Indoor Unit
Install the indoor unit
Approx. 5 - 7 mm
Hook the indoor unit onto the
3. FOR THE EMBEDDED PIPING
upper portion of installation
plate. (Engage the indoor unit
Step-1
Replace the drain hose
with the upper edge of the
Bushing for tube
installation plate). Ensure the
assembly
hooks are properly seated
on the installation plate by
Step-2
Bend the embedded piping
moving it in left and right.
Putty or caulking compound
Use a spring bender or equivalent to bend
the piping so that the piping is not crushed.
Secure the Indoor Unit
Pull the connection cable into Indoor
Step-3
Unit
Press the lower left and right
side of the unit against the
The power supply cord and indoor unit
installation plate until hooks
and outdoor unit connection cable can be
engages with their slot (sound
connected without removing the front grille.
click).
Step-4
Cut and fl are the embedded piping
When determining the dimensions of the
Insert the connection cable
piping, slide the unit all the way to the left
2
(2.0HP), type designation
on the installation plate.
Refer to the section "Cutting and fl aring
the piping".
Step-5
Install the Indoor Unit
2
(3/4 ~ 1.75HP) or 4 x
Step-6
Connect the piping
Please refer to "Connecting the piping"
column in outdoor unit section. (Below
steps are done after connecting
the outdoor piping and gas-leakage
WARNING
To take out the unit, push
confi rmation.)
the
marking at the
This equipment must be
Step-7
Insulate and fi nish the piping
bottom unit, and pull it
properly earthed.
slightly towards you to
Please refer to "Insulation of piping
disengage the hooks
connection" column as mentioned in
from the unit.
indoor/outdoor unit installation.
Control
Step-8
Secure the Indoor Unit
Board
(This can be used for left rear piping and bottom piping also.)
Earth Wire
longer than
others
Exchange the drain hose and
AC wires
the cap
for safety
reason
Rear view for left piping installation
Holder
Tape
Drain hose
Connection cable
Drain hose
Drain cap
Adjust the piping slightly
Connection cable
downwards.
How to pull the piping and drain hose out, in case of the
embedded piping.
Apply putty or
caulking material
to seal the wall
Connection cable
opening.
Piping
Drain hose
from main unit
PVC tube (VP-65) for piping
and connection cable
PVC tube for drain
PVC tube for drain hose (VP-30)
hose (VP-20)
PVC tube
Cable
for drain
hose
Piping
Cracked Uneven
Indoor unit
thickness
100 mm
1
SELECT THE BEST LOCATION
(Refer to "Select the best location" section)
2
INSTALL THE OUTDOOR UNIT
Piping
After selecting the best location, start installation to Indoor/Outdoor Unit Installation Diagram.
1.
Fix the unit on concrete or rigid frame fi rmly and horizontally by bolt nut (ø10 mm).
2.
When installing at roof, please consider strong wind and earthquake.
Please fasten the installation stand fi rmly with bolt, screws or nails.
A
B
Shock absorber
5
Piping
CONNECT THE CABLE TO THE OUTDOOR UNIT
Cover for
the left
Cover for the
piping
bottom piping
Cover for the
1.
Remove the control board cover from the unit by loosening the screw.
bottom piping
Connection cable between indoor unit and outdoor unit shall be
2.
approved polychloroprene sheathed 4 x 1.5 mm
2.5 mm
2
(2.0HP) fl exible cord, type designation 60245 IEC 57 or heavier
Cover for piping
cord. Do not use joint connection cable. Replace the wire if the existing
wire (from concealed wiring, or otherwise) is too short.
Terminals on the outdoor unit
Colour of wires (connection cable)
Terminals on the indoor unit
L
1
3.
Secure the cable onto the control board with the holder (clamper).
4.
Attach the control board cover back to the original position with screw.
For wire stripping and connection requirement, refer to instruction 5 of
5.
indoor unit.
Piping
Cover for
Cover for
the left
the bottom
piping
Cover for
piping
the right
piping
Hooks at installation
plate
6
Sleeve for piping hole
Piping

PIPING INSULATION

Drain hose
Indoor unit
1.
Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap the
insulated piping end to prevent water from going inside the piping.
2.
If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E FOAM with
thickness 6 mm or above.
Installation
Unit's hook
plate
Connection cable
HOW TO TAKE OUT FRONT GRILLE
Gas side piping
Please follow the steps below to take out front grille if necessary
such as when servicing.
Liquid side piping
1.
Set the vertical airfl ow direction louvers to the horizontal
Guide
position.
Drain hose
Connection cable
surface
2.
Remove the 2 caps on the front grille as shown in the
illustration at right, and then remove the 3 mounting screws.
3.
Pull the lower section of the front grille towards you to
remove the front grille.
When reinstalling the front grille, carry
out above step 2 - 3 in the reverse order.
AUTO SWITCH OPERATION
The below operations will be performed by pressing the "AUTO" switch.
1.
AUTO OPERATION MODE
The Auto operation will be activated immediately once the Auto Switch is pressed and release before 5 sec..
2.
TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)
The Test Run operation will be activated if the Auto Switch is pressed continuously for more than 5 sec. to
below 8 sec..
A "pep" sound will occur at the fi fth sec., in order to identify the starting of Test Run operation.
3.
HEATING TRIAL OPERATION
Press the "AUTO" switch continuously for more than 8 sec. to below 11 sec. and release when a "pep pep"
Connection cable
sound is occured at eight sec. (However, a "pep" sound is occurred at fi fth sec..) Then press Remote controller
"A/C Reset" button once.
Piping
More than 950 mm
Remote controller signal will activate operation to force heating mode.
4.
REMOTE CONTROLLER RECEIVING SOUND ON/OFF
The ON/OFF of Remote controller receiving sound can be change over by the following steps:
Drain hose
a) Press "AUTO" switch continuously for more than 16 sec. to below 21 sec..
Sleeve for piping hole
A "pep", "pep", "pep", "pep" sound will occur at the sixteenth sec..
b) Press the "A/C Reset" button once. Remote controller signal will activate the Remote controller sound setting
In case of left piping how to insert the
mode.
connection cable and drain hose.
c) Press the "AUTO" switch once to select Remote controller receiving sound ON/OFF. A "peep" sound indicates
receiving sound ON, and a "pep" sound indicates receiving sound OFF.
5.
HEATING ONLY OPERATION
Press the "AUTO" switch continuously for more than 8 sec. to below 11 sec. And release when a "pep pep" sound
is occurred at eighth sec. (However, a "pep" sound is occurred at fi fth sec.) Then press Remote controller "Check"
button once. Remote controller signal will activate heating only operation mode.
DISPOSAL OF OUTDOOR UNIT DRAIN WATER
If a drain elbow is used, the unit should be placed on a stand which is taller than 3 cm.
Drain
If the unit is used in an area where temperature falls below 0°C for 2 or 3 days in
hose
succession, it is recommended not to use a drain elbow, for the drain water freezes
and the fan will not rotate.
Cable
Piping
(For the right piping, follow the same procedure)
OUTDOOR UNIT
3
CONNECT THE PIPING
Connecting The Piping to Indoor
For connection joint location at outside building
Please make flare after inserting flare nut (locate at joint
portion of tube assembly) onto the copper pipe. (In case of
using long piping)
Connect the piping
Align the center of piping and suffi ciently tighten the fl are
nut with fi ngers.
Further tighten the fl are nut with torque wrench in specifi ed
torque as stated in the table.
Model
A
B
C
D
Z7***, XZ7***
570 mm
105 mm
18.5 mm
320 mm
Z9***, XZ9***
Z12***, XZ12***
540 mm
160 mm
18.5 mm
330 mm
Z15***
Z18***, XZ18***
613 mm
131 mm
16 mm
360.5 mm
Connecting The Piping to Outdoor
Decide piping length and then cut by using pipe cutter.
Remove burrs from cut edge.
Make fl are after inserting the fl are nut (locate at valve)
onto the copper pipe. Align center of piping to valve and
then tighten with torque wrench to the specifi ed torque as
stated in the table.
Terminal Board
2
(3/4 ~ 1.75HP) or 4 x
Earth wire
4
longer than
others
EVACUATION OF THE EQUIPMENT
AC wires
for safety
S1 2
3
reason
Holder
WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the
N
S1 2
3
following procedure.
Indoor & outdoor
connection cable
Do not purge the air with refrigerants but use a vacuum pump to vacuum the installation.
Indoor unit
There is no extra refrigerant in the outdoor unit for air purging.
1.
Connect a charging hose with a push pin to the Low side
WARNING
of a charging set and the service port of the 3-way valve.
Be sure to connect the end of the charging hose with
the push pin to the service port.
This equipment must be properly earthed.
2.
Connect the center hose of the charging set to a
vacuum pump.
Earth wire shall be Yellow/Green (Y/G) in
3.
Turn on the power switch of the vacuum pump and
colour and longer than other AC wires for
make sure that the needle in the gauge moves from
safety reason.
0 cmHg (0 MPa) to –76 cmHg (–0.1 MPa). Then
evacuate the air approximately ten minutes.
4.
Close the Low side valve of the charging set and turn
off the vacuum pump. Make sure that the needle in the
gauge does not move after approximately fi ve minutes.
Note : BE SURE TO TAKE THIS PROCEDURE IN
ORDER TO AVOID REFRIGERANT GAS
LEAKAGE.
5.
Disconnect the charging hose from the vacuum pump
and from the service port of the 3-way valve.
6.
Tighten the service port caps of the 3-way valve at a torque of 18 N•m with a torque wrench.
7.
Remove the valve caps of both of the 2-way valve and 3-way valve. Position both of the valves to "OPEN" using a hexagonal
wrench (4 mm).
Mount valve caps onto the 2-way valve and the 3-way valve.
8.
Be sure to check whole system for gas leakage.
If gauge needle does not move from 0 cmHg (0 MPa) to –76 cmHg (–0.1 MPa), in step 3 above take the following measure:
- If the leak stops when the piping connections are tightened further, continue working from step 3.
- If the leak does not stop when the connections are retightened, repair location of leak.
- Do not release refrigerant during piping work for installation and reinstallation.
- Take care of the liquid refrigerant, it may cause frostbite.
ECO SENSOR
Screw
Do not hit or violently press the sensor.
This can lead to damage and malfunction.
Front
Do not place large objects near the sensor and keep heating units or humidifi ers away
grille
from the sensors detection area.
This may lead to sensor malfunction.
Vane
(Move the vane
to downward)
CHECK THE DRAINAGE
Cap
Open front panel and remove air fi lters.
(Drainage checking can be carried out without removing the front grille.)
Pour a glass of water into the drain tray-styrofoam.
Ensure that water fl ows out from drain hose of the indoor unit.
EVALUATION OF THE PERFORMANCE
Operate the unit at cooling/heating operation mode for fi fteen minutes or more.
Measure the temperature of the intake and discharge air.
Ensure the difference between the intake temperature and the discharge is more
than 8°C during Cooling operation or more than 14°C during Heating operation.
CHECK ITEMS
Drain elbow 7
Hose
Install the hose at an angle so that the
water smoothly fl ows out.
For connection joint location at inside building
Decide the length.
Cut and remove the tube connectors at indoor copper pipings
(both gas and liquid piping) by using pipe cutter. Remove burrs
from cut edge.
Use pipe expander to expand the end of long piping.
Align the center of piping and braze the piping joints.
Indoor
(40~50mm)
Brazing point
copper pipe
Tube connector
Spanner or
Wrench
1. Cut and
2. Expand long
3. Braze both
Torque
Remove
pipe
pipe
wrench
Do not overtighten, overtightening may cause gas leakage.
Piping size
Torque
6.35 mm (1/4")
[18 N•m (1.8 kgf•m)]
9.52 mm (3/8")
[42 N•m (4.3 kgf•m)]
12.7 mm (1/2")
[55 N•m (5.6 kgf•m)]
15.88 mm (5/8")
[65 N•m (6.6 kgf•m)]
19.05 mm (3/4")
[100 N•m (10.2 kgf•m)]
AIR PURGING METHOD IS PROHIBITED FOR R32 SYSTEM
Liquid side
Indoor unit
Outdoor unit
Two-way valve
Close
Gas side
Three-way valve
OPEN
Close
Vacuum
CLOSE
pump
ECO SENSOR
Drain tray-styrofoam
Discharge air
Is there any gas leakage at fl are nut connections?
Is the indoor unit properly hooked to the installation
plate?
Has the heat insulation been carried out at fl are nut
connection?
Is the power supply voltage complied with rated value?
Is the connection cable being fi xed to terminal board
Is there any abnormal sound?
fi rmly?
Is the cooling/heating operation normal?
Is the connection cable being clamped fi rmly?
Is the thermostat operation normal?
Is the drainage ok?
Is the remote control's LCD operation normal?
(Refer to "Check the drainage" section)
Is the earth wire connection properly done?
ENGLISH