< Dual-In-Line Package Intelligent Power Module >
DIPIPM+ Series Application note

CHAPTER 3 : SYSTEM APPLICATION GUIDANCE

3.1 Application guidance

This chapter states the DIPIPM+ application method and interface circuit design hints.

3.1.1 System connection

C1: Electrolytic type with good temperature and frequency characteristics
(note) The capacitance also depends on the PWM
control strategy of the application system
C2: 0.01μ-2μF ceramic capacitor with good temperature,
frequency and DC bias characteristics
C3: 0.1μ-0.22μF Film capacitor (for snubber)
D1: Zener diode 24V/1W for surge absorber
AC line input
R
S
T
Z C
Z : Surge absorber
C : AC filter(ceramic capacitor 2.2n -6.5nF)
(Common-mode noise filter)
Publication Date: September 2016
Inrush
limiting circuit
Braking
resistor
P
P
Brake Di
B
C3
Brake IGBT
N1
N(B)
V
NC
Drive circuit
UV lockout
Input signal
circuit
conditioning
Brake input
Fig.3-1-1 System block diagram (Example)
P-side input
Input signal
Input signal
conditioning
conditioning
Level shift
Level shift
UV lockout
UV lockout
circuit
circuit
Drive circuit
Drive circuit
N
N1
CIN
Drive circuit
Fo Logic
Protection
Input signal
circuit
conditioning
CFo
Fo
N-side input
Fo output
29
C1
Input signal
conditioning
D1
C2
Level shift
UV lockout
circuit
Drive circuit
P-side IGBTs
U
V
W
N-side IGBTs
Temp. output
UV lockout
(SC)
circuit
V
V
OT
NC
(15V line)
DIPIPM+
(CIB type)
M
AC output
C2
C1
D1
V
D