Configuration Of A Redundant Static Route - Hirschmann Power MICE User Manual

Routing configuration industrial ethernet (gigabit) switch
Hide thumbs Also See for Power MICE:
Table of Contents

Advertisement

Static Routing

3.3.2 Configuration of a redundant Static Route

To ensure a reliable connection between the two routers, you can connect
the routers with two or more lines.
Subnet 10.0.1.0/24
10.0.1.5/24
Interface 2.1
IP=10.0.1.1
Figure 11: Redundant static route
You have the option of assigning importance (distance) to a route. If there
are a number of routes to a destination, then the router chooses the route
with the highest importance. If you do not assign a value for the importance
during the configuration, the router takes the preset value "1" for the impor-
tance. This is the highest importance.
enable
configure
interface 2/3
ip address 10.0.4.1
255.255.255.0
routing
exit
ip route 10.0.3.0
255.255.255.0 10.0.4.2 2
show ip route
Routing L3E
Release 4.2 08/08
3.3 Configuration of a Static Route
Interface 2.3
Interface 2.3
IP=10.0.4.1
IP=10.0.4.2
A
Interface 2.2
Interface 2.1
IP=10.0.2.1
IP=10.0.2.2
Switch to the Priviledged EXEC mode.
Switch to the Configuration mode.
Select the port at which you want to connect the
redundant route.
Assign the IP parameters to the port.
Switch on the router function at this port.
Switch to the Configuration mode.
Create the static routing entry for the redundant
route. The "2" at the end of the command is the
value of the importance.
When both routes are available, the router uses
the route via subnet 10.0.2.0/24, because this
route has the higher importance (preset value =
1)
(see on page 30 "Configuration of a Static
Route")
Verify the routing table:
Subnet 10.0.3.0/24
10.0.3.5/24
B
Interface 2.2
IP=10.0.3.1
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mach 4000

Table of Contents