Trouble shooting
Symptom
The fan symbol is
flashing. No heat
and the fan runs at
maximum speed.
The text "Heat OFF"
appears. No heat.
The text "Sens Out"
flashes in the display
and there is no heat.
The text "Sens In"
flashes in the display
and there is no heat.
The fan convector emits
heat, but it becomes
progressively more
difficult to achieve
the desired room
temperature, even
though the settings are
unchanged.
All the fans are inactive. •
Cause
The internal temperature has exceeded
the upper limit, even though the heat is
off. The fans automatically works at the
highest speed and the heat is blocked
until the internal temperature is below
the limit, and then return to the previous
settings.
The control experience that no heat is
emitted from the heating element. (The
temperature difference between the
room sensors and internal sensors is
less than 5 °C after 90 sec.)
The lower sensor is faulty or has beco-
me detached from its fastening.
The upper sensor is faulty or has beco-
me detached from its fastening.
The internal temperature reaches its
limit value faster, which limits the heat
emission.
The fan speed is set to OFF .
The function with fans off at reduced
mode (FRT) is active.
The quick plug for the first motor is
detached.
PFS
Action
Check that the air flow is not
blocked at the intake grille or
outlet grille.
Clean the inside of the unit.
Check that the internal sensor (at
the outlet grille) are placed cor-
rectly.
If the problems continue, please
contact Frico for support.
Check that the air flow is not
blocked at the intake grille or
outlet grille.
Disconnect the power for at least
10 minutes so that the overheat
protection resets.
Reconnect power and cancel the
alarm by pressing the OK button
for 3 seconds.
If the problems continue, please
contact Frico for support.
Please contact Frico for support.
Please contact Frico for support.
Check that the air flow is not
blocked at the intake grille or
outlet grille.
Clean the inside of the unit.
Check that all motors operats cor-
rectly.
If the problems continue, please
contact Frico for support.
Change fan mode to Auto.
Put FRT function to OFF in Set-
tings.
Check the fan motor connections.
If the problems continue, please
contact Frico for support.