Download Print this page

Frico PA3500 Series Original Instructions Manual

Advertisement

Available languages

Available languages

Quick Links

Original instructions
PA3500/4200
SE
GB
NO
FR
DE
.... 27
.... 38
.... 44
.... 50
.... 33
ES
.... 56
NL
PL
.... 82
.... 62
IT
.... 68
.... 74
RU

Advertisement

loading

Summary of Contents for Frico PA3500 Series

  • Page 1 Original instructions PA3500/4200 ..27 ..38 ..44 ..50 ..33 ..56 ..82 ..62 ..68 ..74...
  • Page 2 PA3500/4200 Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene Les pages de présentation contiennent principalement des images.
  • Page 3 PA3500/4200 PA3500 DN20 (3/4"), outside thread PA 2 m; 2,5 m [mm] [mm] PA3510 1039 PA3515 1549 PA3520 2039 2549 PA3525 PA3510/3515: 4 M8 PA3520: 6 M8 SIRe PA3525: 8 M8 [mm] [mm] PA3515 1572 1515 PA3520 2062 2004 PA3525 2572 2515...
  • Page 4 PA3500/4200 PA4200 DN20 (3/4"), outside thread PA 2 m; 2,5 m [mm] [mm] PA4210 1039 PA4215 1549 PA4220 2039 PA4225 2549 PA4210/4215: 4 M8 PA4220: 6 M8 SIRe PA4225: 8 M8 [mm] [mm] PA4215* 1572 1515 PA4220* 2062 2004 PA4225* 2572 2515...
  • Page 5 PA3500/4200 Fig. 1A: Open the unit by raising the front panel. The front Fig. 1B: When the front has been removed it it important is blocked in open position with the front hatch hook. to be sure it is firmly seated in the front locks again. SIRe Fig.
  • Page 6 PA3500/4200 Filling the water coil Fig. 4 [mm] PA3510 PA4210 PA3515 1260 1260 PA4215 PA3500 PA4200 Fig. 5: M8-holes for mounting.
  • Page 7 PA3500/4200 PA3500/4200 + PA34WB PA34WB 20 mm PA34WB15 2 pcs PA34WB20 3 pcs PA34WB30 4 pcs Fig. 6: See separate manual for PA34WB.
  • Page 8 PA3500/4200 PA34CB PA34TR (PA34VD) PA34WS (PA34CB) Fig. 7: PA34TR + PA34CB + PA34VD. Fig.8: PA34WS + PA34CB See separate manual for PA34TR. See separate manual for PA34WS. PA3JK PA4JK Fig. 9: See separate manual for PA3JK / PA4JK. PA3XT PA4XT Fig.
  • Page 9 PA3500/4200 Note! The air curtain must be secured in the wall or ceiling. PA3VDW PA4VDW PA3JK PA4JK Fig. 11: See separate manual for PA3JK / PA4JK.
  • Page 10 PA3500/4200 Accessories PA34WB15 PA3510/15, PA4210/15, 400 mm Fig. 6 PA34WB20 PA3520, PA4220, 400 mm Fig. 6 PA34WB30 PA3525, PA4225, 400 mm Fig. 4 PA34CB15 PA3510/15, PA4210/15 Fig. 7/8 PA34CB20 PA3520, PA4220 Fig. 7/8 PA34CB30 PA3525, PA4225 Fig. 7/8 PA34WS15 PA3510/15, PA4210/15, 3 m Fig.
  • Page 11 PA3500/4200 Accessories PA3DCS 200-300 mm PA3DCM 300-500 mm PA3DCL 500-900 mm PA3DXT 420 mm PA4DCS PA4200, 200-300 mm PA4DCM PA4200, 300-500 mm PA4DCL PA4200, 500-900 mm PA4DXT PA4200, 420 mm PA3510, PA3515, PA4210, PA4215: 2 pcs PA3520, PA4220: 3 pcs PA3525, PA4225: 4 pcs See separate manual for PA3DC / PA4DC.
  • Page 12 PA3500/4200 Accessories PA3JK PA3500 Fig. 11 PA4JK PA4200 Fig. 11 PA34EF10 PA3510W, PA4210W PA34EF15 PA3515W, PA4215W PA34EF20 PA3520W, PA4220W PA34EF25 PA3525W, PA4225W DTV200S PA2500/4200W FHDN20 PA3500/4200, 350 mm See separate manual for PA34EF . DTV200S See separate manual for FHDN20. PA3VDW15 PA3515 Fig.
  • Page 13 PA3500/4200 Accessories SIRe 673 09 57 SIReB SIReAC 673 09 64 SIReAA 673 09 66 SIReB SIReUR SIReRTX 673 09 22 70x33x23 mm SIReUR 673 09 21 114x70x50 mm SIReWTA SIReWTA SIReCJ4 SIReCJ6 673 09 23 SIReCC603 SIReCC605 673 09 24 SIReAC/SIReAA SIReCC610 673 09 25...
  • Page 14 PA3500/4200 PA3500 A PA4200 A Transformer Transformer SIReB1 Actuator Supply 230V~ 230V~ ROOM...
  • Page 15 PA3500/4200 PA3500 E PA4200 E Transformer Transformer SIReB1 Actuator 230V~ ROOM...
  • Page 16 PA3500/4200 PA3500 W PA4200 W Transformer Transformer SIReB1 Actuator Supply 230V~ 230V~ ROOM...
  • Page 17 PA3500/4200 SIReB Basic PA3500/4200 A SIReB1 SIReUB1 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB Basic - Parallel connection SIReB1 SIReB1 SIReUB1 230V~ 230V~ ROOM ROOM Pot. Pot. Unit ID Unit ID ACTUATOR SUPPLY ACTUATOR SUPPLY Wiring diagrams for SIReAC Competent, see manual for SIRe.
  • Page 18 PA3500/4200 SIReB Basic PA3500/4200 E SIReB1 SIReRTX SIReUB1 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB Basic - Parallel connection SIReB1 SIReB1 SIReRTX SIReUB1 (optional) 230V~ 230V~ ROOM ROOM Pot. Pot. Unit ID Unit ID ACTUATOR SUPPLY ACTUATOR SUPPLY Wiring diagrams for SIReAC Competent and SIReAA Advanced, see manuals for SIRe.
  • Page 19 PA3500/4200 SIReB Basic PA3500/4200 W SIReB1 SD230 SIReRTX SIReUB1 (optional) ROOM 230V~ Pot. Unit ID ACTUATOR SUPPLY...
  • Page 20 PA3500/4200 SIReB Basic - Parallel connection PA3500/4200 W SIReB1 SD230 ROOM 230V~ Pot. Unit ID ACTUATOR SUPPLY SIReB1 SD230 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB1 SIReRTX SIReUB1 SD230 (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY Wiring diagrams for SIReAC Competent and SIReAA Advanced, see manuals for SIRe.
  • Page 21 57,3 0,26 32,4 38,8 0,72 33,6 2200 12,7 44,2 0,08 20,3 45,2 0,45 14,2 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 22 34,9 0,32 11,6 26,7 35,1 0,32 11,7 2200 12,7 29,0 0,12 15,9 39,3 0,19 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 23 4400 20,8 31,6 0,60 19,4 31,0 0,47 2100 10,0 28,4 0,21 10,9 33,3 0,26 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 24 36,6 61,1 0,43 42,6 37,8 0,95 18,3 3020 17,4 47,8 0,12 26,7 44,0 0,59 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 25 35,7 0,46 18,5 35,8 34,7 0,43 16,7 3020 17,5 29,2 0,16 21,5 38,9 0,26 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 26 28,5 32,2 0,89 12,4 25,8 30,7 0,62 2820 13,2 31,8 0,28 14,4 33,1 0,35 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 27 PA3500/4200 Technical specifications |   1 PA3500 A without heat Type Output Airflow* Sound Output- Voltage Amperage Length Weight level* motor motor motor [kW] [dB(A)] [mm] [kg] PA3510A 860/1800 40/57 230V~ 1039 PA3515A 1240/2600 40,5/58,5 230V~ 1549 PA3520A 1530/3200 42/59,5 230V~ 2039 PA3525A...
  • Page 28 PA3500/4200 Technical specifications |   1 PA4200 A without heat Type Output Airflow* Sound Output- Voltage Amperage Length Weight level* motor motor motor [kW] [dB(A)] [mm] [kg] PA4210A 1280/2700 46/63,5 230V~ 1039 PA4215A 1760/3700 46/64 1150 230V~ 1549 PA4220A 2520/5300 47/64,5 1610 230V~...
  • Page 29 Montage- und Betriebsanleitung Montage Allgemeine Anweisungen Die Luftschleierreihe kann für eine Bitte lesen Sie diese Anweisungen vor der waagerechte oder senkrechte Montage Installation und Nutzung gründlich durch. angepasst werden und die Geräte können Bewahren Sie diese Anleitung zum späteren auch in Zwischendecken integriert werden. Nachschlagen gut auf.
  • Page 30 Montage ist als Zubehörteil erhältlich, siehe Mit Wasser beheiztes Gerät Abb. 10 sowie separate Anleitung. Wird über den eingebauten SIRe-Regler mit einem 2-Meter-Kabel und Netzstecker Vertikale Montage PA3JK angeschlossen. Geräte ab einer Länge von 1,5 Metern können senkrecht verwendet werden. Für Elektrisch beheiztes Gerät eine senkrechte Montage muss das Gerät Die Installation erfolgt auf der Oberseite des...
  • Page 31 Strömungsrichtung und die Die Anschlüsse an die Heizspirale müssen Ventilatordrehzahl ggf. Feineinstellungen mit Absperr- und Ablaufventilen (in den erfordern können, je nachdem, wie stark die Ventilsätzen von Frico enthalten) versehen Tür beansprucht wird. sein, um ein problemfreies Entfernen zu gewährleisten. Filter (W) Ein Entlüftungsventil muss an einer höher...
  • Page 32 Wartung und beheben Sie den Fehler. 4. Schließen Sie den Luftschleier wieder an Mit Wasser beheiztes Gerät: die Stromversorgung an. Der Gerätefilter muss regelmäßig gereinigt werden, um die Wirkung des Luftfilters Alle Motoren sind mit einer integrierten und den Wärmeausstoß vom Gerät zu thermischen Sicherung ausgestattet.
  • Page 33 Fehlersuche Zeit nicht im Einsatz ist, sollte es hin und wieder zur Vorbeugung für eine kurze Zeit Wenn die Ventilatoren nicht funktionieren oder nicht eingeschaltet werden. stark genug blasen, prüfen Sie Folgendes: • Ob das Lufteinlassgitter bzw. der Filter Sicherheit verschmutzt ist.
  • Page 34 Übersetzung für Einführungsseiten • Outside thread = Außengewinde • pcs = Stück • See separate manual for xxx = Siehe separate Anleitung für xxx • Accessories = Zubehör • Parallel connection = paralleler Anschluss • Wirings diagrams for xxx, see manual for = Schaltbilder für xxx, SIRe.