7 Troubleshooting
7-1 Power Problem
Power
Problem
Power Out
Ok? SMPS
Y
Power VDRV
(+24V) Ok?
Y
Power VCC
(+5V) Ok?
Y
End
SAM4S ER-600 SERIES
1. Check the Power Cable
N
2. Replace the SMPS.
1. Check the Fuse (FU1) on PCB
N
2. Check the Diode(D36 ,D37, ZD 6) on PCB
3. Check the VDRV signal whether it is short.
N
1. Check the IC34063(U26)
2. Check the TR 1010 (Q14)
3. Check Generated Frequency
4. Check the VCC whether
it is short or open.
7-1