Wifi Data Logger; Technical Data; Measurement-Specific Data - TESTO Saveris 2 Instruction Manual

Wifi data logger system
Hide thumbs Also See for Saveris 2:
Table of Contents

Advertisement

5 WiFi data logger

5
WiFi data logger
5.1

Technical data

5.1.1

Measurement-specific data

WiFi
T1
data
logger
s
Sensor
1x NTC
type
internal
Measu
-30 to +5
ring
0 °C
range
Accura
± 0.5 °C
cy
±1 digit
Resolu
0.1 °C
tion
1
Not for condensing atmosphere. For continuous application in high humidity
(> 80 %RH at ≤ 30 °C for > 12 h, > 60 %RH at > 30 °C for > 12 h), please
contact us (www.testo-international.com).
8
T2
T3
2x NTC
2x
or door
thermocoupl
contact
e type K/J/T
external
external
-50 to +1
K: -195 to +1
50 °C
350 °C
J: -100 to +7
50 °C
T: -200 to +4
00 °C
± 0.5 °C
± (0.5 °C +
0.5% of
reading)
0.1 °C
0.1 °C
(-200 to +999
.9 °C)
1 °C
(residual
range)
H1
H2
1x
1x
NTC/humi
NTC/hu
dity
midity
internal
external
-30 to +50
Probe-
°C
specific
0 to 100
1
%RH
± 0.5 °C
Probe-
specific
±2 %RH
0.1 °C
0.1 °C
0.1%
0.1%

Hide quick links: