Roca P-10 Installation, Assembly And Operating Instructions
Roca P-10 Installation, Assembly And Operating Instructions

Roca P-10 Installation, Assembly And Operating Instructions

Multifuel boiler

Advertisement

P-10
E
Caldera policombustible
Instrucciones de Instalación,
Montaje y Funcionamiento
para el INSTALADOR
Combustibles fluidos
For fluid-fuel firing
GB
Multifuel Boiler
Installation, Assembly
and Working Instructions
for the INSTALLER
Combustibles sólidos
For solid-fuel firing
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P-10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Roca P-10

  • Page 1 P-10 Multifuel Boiler Caldera policombustible Installation, Assembly Instrucciones de Instalación, and Working Instructions Montaje y Funcionamiento for the INSTALLER para el INSTALADOR Combustibles fluidos Combustibles sólidos For fluid-fuel firing For solid-fuel firing...
  • Page 5 42 – Interruptor del circulador / Pump On/off switch 43 – Interruptor del quemador / Burner On/off switch 44 – Termostato de regulación / Control thermostat 45 – Termostato de seguridad / Limit termostat 46 – Termohidrómetro / Combined temp./altitude gauge...
  • Page 6 53 - Recogedor / Shovel 54 - Rastrillo / Scraper 55 - Atizador / Slice bar 56 - Cepillo rectangular, con mango / Flue brush with handle...
  • Page 7 Esquema de conexionado / Wiring diagram Interruptor circulador Pump On/off switch Circulador Pump Termostato ambiente Ambient thermostat Interruptor puerta quemador Burner door microswitch Interruptor quemador Burner On/off switch Termostato regulación Control thermostat Termostato seguridad Limit thermostat Quemador Burner Nota: Si se coloca termostato ambiente, deshacer el puente existente entre los bornes 5 y 6. Note: Where an ambient thermostat has been installed, remove the jumper across terminals 5 and 6.
  • Page 8: Main Features

    Approx. Type Sections content Pressure Efficiency Volume Volume Weight runaway Efficiency Weight Drop Equipment Litres mm.w.g. kcal/h kcal/h P-10-3 0,10 7.000 10.000 11,6 P-10-4 0,15 10.000 11,6 14.000 16,3 P-10-5 0,20 13.000 15,1 10,0 18.000 20,9 (1) Output obtained with coal - Granulometry 20 ÷...
  • Page 9 Controls 8 - If it is decided to fit a combined temperature/altitude gauge 1 - The P-10 boiler for solid fuels is delivered in two packages: in boilers intended for continuous use of solid fuels*, the Pack 1 - Fully assembled boiler body, painted with an anti-...
  • Page 10 Safety against opening the firedoor Fitting the control panel It is impossible to open the firedoor accidentally once the The control panel that is supplied with the complementary burner door (16) is immobilized since the flange (24) makes it equipment for using fluid fuels incorporates the relative parts, impracticable.
  • Page 11: Important Recommendations

    10 - Set the automatic damper regulator according to the instructions that come with it. 11 - Bleed all the radiators and ensure that they reach the required operating temperature in accordance with that selected on the damper regulator. First lighting with fluid fuels 5 - Connect the fuel supply line to the burner.

Table of Contents