TriggerControl
TriggerControl features are related to image acquisition using trigger.
This camera series provides two kinds of exposure synchronization.
1. Normal Shutter mode
2. Random Trigger Shutter mode
In Random Trigger Shutter mode, two kinds of trigger input are available.
1. Trigger signal via the I/O connector (HardwareTrigger)
2. Trigger command via software command (SoftwareTrigger)
The following table shows the combination of operation mode of this camera series.
Trigger Mode
Normal Shutter mode
Random Trigger Shutter mode
Copyright © 2017 TOSHIBA TELI CORPORATION, All rights reserved.
: Free run operation (internal synchronization)
: Synchronized with external trigger input
Operation Mode
Synchronization
Free run
-Edge mode:TriggerSequence0
-Bulk mode:TriggerSequence6
HardwareTrigger
-Level mode:TriggerSequence1
-Edge mode:TriggerSequence0
SoftwareTrigger
-Bulk mode:TriggerSequence6
* The camera operation not mentioned above is not supported.