● Control with TeliCamSDK
There are three way to access this feature.
Camera feature API
This API is dedicated to AcquisitionControl.
GetCamAcquistionFrameCountMinMax
GetCamAcquistionFrameRateControl
SetCamAcquistionFrameRateControl
GetCamAcquistionFrameRateMinMax
1. Set the number of frames to transfer in MultiFrame/ImageBuffer mode. (optional)
Set 'AcquisitionFrameCount' with 'SetCamAcquistionFrameCount' function.
*If yo
u want to capture image stream continuously, it's not necessary to set an AcquisitionFrameCount.
2. Select an 'AcquisitionFrameRate' setting priority. (optional)
Set 'AcquisitionFrameRateControl' with 'SetCamAcquistionFrameRateControl' function.
AcquisitionFrameRateControl
NoSpecify (*)
Manual
3. Set frame rate of image stream. (optional)
Set 'AcquisitionFrameRate' with 'SetCamAcquistionFrameRate' function.
Or, set 'AcquisitionFrameInterval' with 'SetCamAcquistionFrameInterval' function.
'AquisitionFrameInterval' is a reciprocal of 'AcquisitionFrameRate'.
Please refer to [Controlling camera feature functions] in [TeliCamAPI Library manual] for more detail.
4. Capture image stream.
TeliCamAPI provides streaming functions including command handling and buffer handling to
capture image stream simply.
Please refer to [Camera streaming functions] in [TeliCamAPI Library manual] and
[GrabStreamSimple] sample code in your TeliCamSDK install folder.
Copyright © 2017 TOSHIBA TELI CORPORATION, All rights reserved.
API name
GetCamAcquistionFrameCount
SetCamAcquistionFrameCount
GetCamAcquistionFrameRate
SetCamAcquistionFrameRate
The frame rate is determined by giving priority to ExposureTime setting value.
The frame rate is determined by giving priority to AcquisitionFrameRate setting value.
Description
Get minimum and maximum value
Get current value
Set new value
Get current value
Set new value
Get minimum and maximum value
Get current value
Set new value
Function