● Control with TeliCamSDK
GenICam function API
Control BayerProcessingMode using GenICam API.
 BayerProcessingMode
Select BayerProcessingMode by 'BayerProcessingMode'.
Integer value and string value of Enumeration are as follows.
// GenICam node handle
CAM_NODE_HANDLE hMode = NULL;
// Retrieve GenICam node.
Nd_GetNode(s_hCam, "BayerProcessingMode", &hMode);
// BayerProcessingMode = Raw
Nd_SetEnumStrValue(s_hCam, hMode, "Raw");
Please refer to [INode functions], [IEnumeration node functions] in [TeliCamAPI Library manual] for
more detail.
Register access API
This API access IIDC2 registers directly.
 BayerProcessingMode
Write to 'Value' field of 'BayerProcessingMode' register.
// BayerProcessingMode = Raw
uint32_t
uiMode = 0;
Cam_WriteReg(s_hCam, 0x21F43C, 1, &uiMode);
Please refer to [Camera functions] in [TeliCamAPI Library manual] for more detail.
● Note
Changing 'BayerProcessingMode' register value is invalid during image stream data output.
Copyright © 2017 TOSHIBA TELI CORPORATION, All rights reserved.
Integer
0
8
16
API name
Cam_ReadReg
Cam_WriteReg
uiMode;
68 / 179
String
Raw
Partial
Full
Description
Read register value
Write register value
http://www.toshiba-teli.co.jp/en/