GenICam function API
Control Trigger features using GenICam API.
1. Select a trigger mode by 'TriggerMode'.
Integer value and string value of Enumeration are as follows.
2. Select a trigger sequence of random trigger shutter by 'TriggerSequence'.
Integer value and string value of Enumeration are as follows.
3. Select a trigger source of random trigger shutter by 'TriggerSource'.
Integer value and string value of Enumeration are as follows.
4. Select a trigger activation of hardware trigger by 'Trigger Activation.
5. Set the number of frames to exposure in Bulk mode by 'TriggerAdditionalParameter'.
6. Set a trigger delay by 'TriggerDelay'.
7. Capture image stream.
To start and stop capturing image is the same way as AcquisitionControl.
Please refer to [Camera streaming functions] in [TeliCamAPI Library manual] and
[GrabStreamSimple] sample code in your TeliCamSDK install folder.
8. Execute software trigger in SoftwareTrigger mode by 'TriggerSoftware'.
9. Receive Image
10. Stop and Close image stream.
Copyright © 2017 TOSHIBA TELI CORPORATION, All rights reserved.
Integer
String
0(*)
Off
1
On
* initial factory setting
Integer
String
0(*)
TriggerSequence0
1
TriggerSequence1
6
TriggerSequence6
* initial factory setting
Integer
String
0(*)
Line0
2
Line2
64
Software
* initial factory setting