Revision 0 10640I00.Slk - Honeywell KHF 1050 System Installation Manual

Hf communication system
Hide thumbs Also See for KHF 1050:
Table of Contents

Advertisement

Preliminary - Subject to Change Without Notice
NOTE: Due to the high level of RF voltage the KHF 1050
The KAC 1052 must be mounted in a location that will allow
it to be well bonded to the airframe. See Section 6A for
bonding considerations.
For best reliability, the KAC 1052 should be mounted such
that it is not subjected to excessive vibration or heat.
The KAC 1052 can be mounted to either vertically or
horizontally on a horizontal surface.
5.B.(2) KPA 1052 Power Amplifier Mounting Location
Refer to Figure 2031 for mounting dimensions.
The location of the KPA 1052 is generally not critical.
It is recommended that it be mounted near the KAC 1052,
to minimize loss in the coaxial cable interconnecting the
KPA 1052 and the KAC 1052.
The cable length between the KPA 1052 and the KAC 1052
should not exceed 50 feet.
For best reliability, the KAC 1052 should be mounted such
that it is not subjected to excessive vibration or heat.
The KAC 1052 can be mounted to either a vertical or
horizontal surface.
5.B.(3) KRX 1053 Receiver/Exciter Mounting Location
Refer to Figure 2032 for mounting dimensions.
Mount the KRX 1053 so that the connection between the KRX
1053 and the KAC 1052 does not exceed 50 feet. The KRX
1053 is typically mounted vertically on a horizontal
surface.
Revision 0
10640I00.SLK
N
KHF 1050 SYSTEM INSTALLATION MANUAL
system is capable of generating, only a specially
fabricated Honeywell feedline may be used. Refer to
Section 1.C.(1) for appropriate part numbers.
23-10-09
Page 2003
Mar/2003

Hide quick links:

Advertisement

Table of Contents
loading